Active functional stiffness of the knee joint during activities of daily living: a parameter for improved design of prosthetic limbs.

نویسندگان

  • Hande Argunsah Bayram
  • Chih-Hao Chien
  • Brian L Davis
چکیده

BACKGROUND Exploring knee joint physiological functional stiffness is crucial for improving the design of prosthetic legs that aim to mimic normal gait. This study hypothesizes that knee joint stiffness varies among different activities of daily living, additionally while the knee performs natural movements; the magnitude of the stiffness indicates the degree of energy storage element sufficiency in terms of harvesting/returning energy. METHODS This study examined sagittal plane knee moment vs. knee flexion angle curves from 12 able-bodied subjects during activities of daily living. Slopes of these curves were assessed to find the calculated stiffness during the peak energy return and harvest phases so that the activities, which can be performed when the prosthetic knee is supplemented by a spring, were identified. FINDINGS For the energy return and harvest phases, the stiffness varied between 0.006 and 0.046 Nm/kg deg. and 0 and 0.052 Nm/kg deg. respectively. The optimum energy return phase stiffness was 0.024 (SD 0.013) Nm/kg deg. and energy harvest phase stiffness was 0.011 (SD 0.018) Nm/kg deg. INTERPRETATION Knee joint stiffness varied significantly during activities of daily living, which indicated that a storage unit with a constant stiffness would not be sufficient in providing energy regenerative gait during all activities. However, by controlling the amount and timing of spring compression and release, an energy-regenerative prosthetic knee device could be developed during most of the activities. This study was directed to the development of a complete data set, which determined the torque-angle properties of the healthy knee joint.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Knee Fusion or Above-The-Knee Amputation after Failed Two-Stage Reimplantation Total Knee Arthroplasty

Prosthetic joint infection (PJI) is a serious complication of total knee arthroplasty (TKA). Control of infection after a failed two-stage TKA is not always possible, and the resolution of infection may require an above-knee amputation (AKA) or a the-knee (KF). The purpose of this review is to determine which treatment method (AKA or KF) yields better function and ambulatory status for patients...

متن کامل

Self-reported knee joint instability is related to passive mechanical stiffness in medial knee osteoarthritis

BACKGROUND Self-reported knee joint instability compromises function in individuals with medial knee osteoarthritis and may be related to impaired joint mechanics. The purpose of this study was to evaluate the relationship between self-reported instability and the passive varus-valgus mechanical behaviour of the medial osteoarthritis knee. METHODS Passive varus-valgus angular laxity and stiff...

متن کامل

Comparison of the Effect of 8 Weeks of Land Exercise Therapy and Hydrotherapy on Functional Activities of Elderly Women with Knee Osteoarthritis

Objectives: Knee osteoarthritis is one of the most common musculoskeletal problems in older adults. Pain, stiffness, tenderness, decreased muscle strength and joint range of motion, impaired proprioception, and balance problems lead to impaired physical function, making the person incapable of performing functional activities. Therefore, it is necessary to use strategies to control and reduce t...

متن کامل

The Impact of Self-Acupressure on the Pain, Joint Stiffness and Physical Functioning of Patients with Knee Osteoarthritis

Background: People with knee osteoarthritis have a low quality of life due to joint pain and stiffness that severely limits their daily activities.  This study aims to investigate the impact of self-acupressure on the pain, joint stiffness and physical functioning of patients with osteoarthritis. Methods: This randomized clinical trial was conducted on 78 patients aged 50 to 70 years with knee...

متن کامل

The effect of total knee arthroplasty on joint movement during functional activities and joint range of motion with particular regard to higher flexion users.

PURPOSE To evaluate active and functional knee excursion of patients before and after total knee arthroplasty (TKA) and to determine whether TKA restores quality of life related to functional activities of daily living. METHODS Electrogoniometry was used to measure the functional movement of the knee during 11 activities of daily living in 50 patients who underwent TKA. These data were compar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical biomechanics

دوره 29 10  شماره 

صفحات  -

تاریخ انتشار 2014