The Leicester Cough Monitor: preliminary validation of an automated cough detection system in chronic cough.

نویسندگان

  • S S Birring
  • T Fleming
  • S Matos
  • A A Raj
  • D H Evans
  • I D Pavord
چکیده

Chronic cough is a common condition that presents to both primary and secondary care. Assessment and management are hampered by the absence of well-validated outcome measures. The present study comprises the validation of the Leicester Cough Monitor (LCM), an automated sound-based ambulatory cough monitor. Cough frequency was measured with the LCM and compared with coughs and other sounds counted manually over 2 h of a 6-h recording by two observers in nine patients with chronic cough in order to determine the sensitivity and specificity of the LCM. Automated cough frequency was also compared with manual counts from one observer in 15 patients with chronic cough and eight healthy subjects. All subjects underwent 6-h recordings. A subgroup consisting of six control and five patients with stable chronic cough underwent repeat automated measurements > or = 3 months apart. A further 50 patients with chronic cough underwent 24-h automated cough monitoring. The LCM had a sensitivity and specificity of 91 and 99%, respectively, for detecting cough and a false-positive rate of 2.5 events x h(-1). Mean+/-SEM automated cough counts x patient x h(-1) was 48+/-9 in patients with chronic cough and 2+/-1 in the control group (mean difference 46 counts x patient x h(-1); 95% confidence interval (CI) 20-71). The automated cough counts were repeatable (intra-subject SD 11.4 coughs x patient x h(-1); intra-class correlation coefficient 0.9). The cough frequency in patients undergoing 24-h automated monitoring was 19 coughs x patient x h(-1); daytime (08:00-22:00 h) cough frequency was significantly greater than overnight cough frequency (25 versus 10 coughs x patient x h(-1); mean difference 15 coughs x patient x h(-1), 95% CI 8-22). The Leicester Cough Monitor is a valid and reliable tool that can be used to assess 24-h cough frequency in patients with cough. It should be a useful tool to assess patients with cough in clinical trials and longitudinal studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Local immunodiagnosis of pulmonary TB: ELISPOT or flow cytometry, PPD or ESAT-6?

REFERENCES 1 Birring SS, Fleming T, Matos S, Raj AA, Evans DH, Pavord ID. The Leicester Cough Monitor: preliminary validation of an automated cough detection system in patients with chronic cough. Eur Respir J 2008; 31: 1013–1018. 2 Birring SS, Matos S, Patel RB, Prudon B, Evans DH, Pavord ID. Cough frequency, cough sensitivity and health status in patients with chronic cough. Respir Med 2006; ...

متن کامل

Pleuroparenchymal fibroelastosis as a manifestation of chronic lung rejection?

Statement of Interest: Statements of interest for S. Birring and I. Pavord can be found at www.erj.ersjournals.com/site/misc/ statements.xhtml REFERENCES 1 Pavord ID, Chung KF. Management of chronic cough. Lancet 2008; 371: 1375–1384. 2 Morice AH, McGarvey L, Pavord ID. Recommendations for the management of cough in adults. Thorax 2006; 61: 1–24. 3 Birring SS, Fleming T, Matos S, et al. The Lei...

متن کامل

The Leicester Cough Monitor: a semi-automated, semi-validated cough detection system?

Objective cough monitoring is an important development in the assessment of cough, but it is technically challenging. It is essential that systems designed to automatically detect cough are carefully validated. The recent study by BIRRING et al. [1] reports ''the validation of the LCM and preliminary findings of 6-and 24-h recordings in patients with chronic cough''. One could be forgiven for i...

متن کامل

Cough frequency monitors: can they discriminate patient from environmental coughs?

BACKGROUND Objective cough frequency measurements are increasingly applied in clinical research. Technological advances enable automated detection and counting of cough events from sound recordings of many hours' duration. A possible limitation of sound-based cough frequency measurement is the contamination of recordings by environmental coughs (coughs from persons other than the patient). This...

متن کامل

Cough frequency, cough sensitivity and health status in patients with chronic cough.

BACKGROUND Little is known about the frequency of cough in health and in patients with chronic cough. METHODS We measured cough frequency and its relationship with other markers of cough severity in 20 patients with chronic cough and 9 healthy subjects using the Leicester Cough Monitor (LCM), which is an automated ambulatory digital cough monitor that records sound only. All subjects had a 6-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 31 5  شماره 

صفحات  -

تاریخ انتشار 2008