Indoor PM1, PM2.5, PM10 and outdoor PM2.5 concentrations in primary schools in Sari, Iran.

نویسندگان

  • Mahmoud Mohammadyan
  • Bijan Shabankhani
چکیده

This study was carried out to determine the distribution of particles in classrooms in primary schools located in the centre of the city of Sari, Iran and identify the relationship between indoor classroom particle levels and outdoor PM2.5 concentrations. Outdoor PM2.5 and indoor PM1, PM2.5, and PM10 were monitored using a real-time Micro Dust Pro monitor and a GRIMM monitor, respectively. Both monitors were calibrated by gravimetric method using filters. The Kolmogorov-Smirnov test showed that all indoor and outdoor data fitted normal distribution. Mean indoor PM1, PM2.5, PM10 and outdoor PM2.5 concentrations for all of the classrooms were 17.6 μg m(-3), 46.6 μg m(-3), 400.9 μg m(-3), and 36.9 μg m(-3), respectively. The highest levels of indoor and outdoor PM2.5 concentrations were measured at the Shahed Boys School (69.1 μg m(-3) and 115.8 μg m(-3), respectively). The Kazemi school had the lowest levels of indoor and outdoor PM2.5 (29.1 μg m(-3) and 15.5 μg m(-3), respectively). In schools located near both main and small roads, the association between indoor fine particle (PM2.5 and PM1) and outdoor PM2.5 levels was stronger than that between indoor PM10 and outdoor PM2.5 levels. Mean indoor PM2.5 and PM10 and outdoor PM2.5 were higher than the standards for PM2.5 and PM10, and there was a good correlation between indoor and outdoor fine particle concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی غلظت ذرات قابل استنشاق در کلاس های مدارس ابتدایی مرکز شهر ساری

Background and purpose: High concentrations of respirable particles in both the outdoor and indoor environments are associated with adverse health effects that could reduce the performance of students. This study was carried out to investigate the indoor concentrations of respirable particle and outdoor concentrations of PM2.5 at classrooms in primary schools in Sari, north of Iran. We also eva...

متن کامل

Indoor–outdoor concentrations of particulate matter in nine microenvironments of a mix-use commercial building in megacity Delhi

Three naturally and six mechanically ventilated microenvironments (MEs) of a mixed use commercial building in Delhi are used to study indoor–outdoor (I/O) relationships of particulate matter ≤10μm (PM10), ≤2.5μm (PM2.5) and ≤1μm (PM1). Effect of environmental and occupancy parameters on the concentrations of PM during working and non–working hours (i.e. activity and non-activity periods, respec...

متن کامل

بررسی غلظت ذرات معلق در هوای داخل کلاس و هوای بیرون و عوامل تأثیرگذار آن در مدارس راهنمایی و دبیرستان شهر یزد

Abstract Introduction: Airborne pollution in such public environments as schools has adverse health effects on pupils and teachers who spend a noticeable amount of time in the school. Therefore, this study aimed to measure the suspended particles concentration of indoor and outdoor air of Yazd schools as well as to determine the influencing parameters on the pollution intensity. Metho...

متن کامل

Evaluation of Indoor-Outdoor Particle Size Distribution in Tehran's Elementary Schools

A simultaneous study on indoor and outdoor particulate matter concentrations was done in five elementary schools in central parts of Tehran, Iran. Three sizes of particles including PM10, PM2.5 and PM1.0 were measured in 13 classrooms within this schools during winter (January, February and March) 2009. A laserbased portable aerosol spectrometer Model Grimm-1.108, was used for the continuous me...

متن کامل

Short-term effects of particle size fractions on circulating biomarkers of inflammation in a panel of elderly subjects and healthy young adults.

Systemic inflammation biomarkers have been associated with risk of cardiovascular morbidity and mortality. We aimed to clarify associations of acute exposure to particulate matter (PM10 (PM < 10 μm), PM2.5-10 (PM 2.5-10 μm), PM2.5 (PM < 2.5 μm), PM1-2.5 (PM 1-2.5 μm), and PM1 (PM < 1 μm)) with systemic inflammation using panels of elderly subjects and healthy young adults. We followed a panel o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arhiv za higijenu rada i toksikologiju

دوره 64 3  شماره 

صفحات  -

تاریخ انتشار 2013