Non-contrast-enhanced pulmonary vein MRI with a spatially selective slab inversion preparation sequence.

نویسندگان

  • Peng Hu
  • Michael L Chuang
  • Kraig V Kissinger
  • Beth Goddu
  • Lois A Goepfert
  • Neil M Rofsky
  • Warren J Manning
  • Reza Nezafat
چکیده

We propose a non-contrast-enhanced, three-dimensional, free-breathing, electrocardiogram-gated, gradient recalled echo sequence with a slab-selective inversion for pulmonary vein (PV) MRI. A sagittal inversion slab was applied prior to data acquisition to suppress structures adjacent to the left atrium (LA) and PVs, thereby improving the conspicuity of the PV and LA. Compared with other MR angiography methods using an inversion pulse, the proposed method does not require signal subtraction and the inversion slab is not parallel to the imaging slab. The feasibility of the proposed method was demonstrated in healthy subjects. The inversion slab thickness and inversion time were optimized to be 60 mm and 500 ms, respectively. Compared to conventional gradient recalled echo imaging without inversion, the proposed technique significantly increased the contrast-to-noise ratios between the LA and the right atrium by 20-fold (P < 0.01), increased the contrast-to-noise ratios between the PVs and right atrium by 10-fold (P < 0.03), and increased the contrast-to-noise ratios between the PVs, LA and pulmonary artery by 4-fold (P < 0.01 for both). The signal-to-noise ratios of the PVs and the LA were similar with and without the inversion slab (P > 0.3). The proposed technique greatly enhances the conspicuity of the PVs and LA without significant loss of signal-to-noise ratio.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-Contrast Enhanced Pulmonary Vein MRA with a Spatially Selective Inversion Preparation Sequence

Introduction: Non-contrast enhanced pulmonary vein (PV) MRA is an alternative to contrast-enhanced PV imaging for assessment of PV anatomy prior to and after PV isolation as a treatment for atrial fibrillation (AF) (1,2). We propose a non-contrast enhanced three-dimensional (3D) free-breathing ECG-gated thin-slab spoiled gradient recalled echo (GRE) sequence with a slab-selective inversion for ...

متن کامل

Free-breathing renal MR angiography with steady-state free-precession (SSFP) and slab-selective spin inversion: initial results.

BACKGROUND The aim of our study was the investigation of a novel navigator-gated three-dimensional (3D) steady-state free-precession (SSFP) sequence for free-breathing renal magnetic resonance angiography (MRA) without contrast medium, and to examine the advantage of an additional inversion prepulse for improved contrast. METHODS Eight healthy volunteers (mean age 29 years) and eight patients...

متن کامل

3D Time-of-Flight MRA Using Inversion Recovery TrueFISP

A major drawback of 3D time-of-flight (TOF) sequences is progressive saturation of inflowing spins along the slab direction, and a sufficient long TR or shaped excitation pulses are required to compensate for this. Here we present a new TOF technique based on a combination of selective inversion and 3D acquisition with TrueFISP. The stationary tissue is partially suppressed by the inversion pul...

متن کامل

A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla.

BACKGROUND The breathhold contrast-enhanced three-dimensional magnetic resonance angiography (MRA) using T1-weighted gradient-echo imaging sequence is the standard technique for MRA of the thorax. However, this technique is not desirable for certain patients with respiratory insufficiency, serious renal impairment, or allergy to contrast agents. The objective of this study was to optimize and e...

متن کامل

Non-Contrast-Enhanced Renal Venography Using Spatial Labeling With Multiple Inversion Pulses ( SLEEK )

Renal venogram is often used to diagnose renal vein thrombosis or evaluate renal venous system for kidney transplant patients and donors. The existing MRI technique for renal venogram is delayed Gd enhanced MRA. The contrast enhanced technique has its limitations: 1: the arterial contamination; 2: the potential association between the gadolinium-contrast and the nephrogenic systemic fibrosis (N...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 63 2  شماره 

صفحات  -

تاریخ انتشار 2010