The aim of this study was to evaluate the effect of water irrigation on heat dissipation kinetics following abutment preparation of 1-piece dental implants. UNO 1-piece dental implants were mounted on Plexiglas apparatus clamping the implant at the collar. T-type thermocouple was attached to the first thread of the implant and recorded thermal changes at 100 millisecond intervals. Implants were prepared using highspeed dental turbine at 400,000 RPM with a coarse diamond bur. Once temperature reached 47 degrees C, abutment preparation was discontinued. Thirty implants were divided into 2 groups. Group A: Passive cooling without water irrigation. Group B: Cooling with turbine's water spray adjacent to the implant (30 mL/min). The following parameters were measured: T47 (time from peak temperature to 47 degrees C), T50%, T75% (time until the temperature amplitude decayed by 50% and 75%, respectively), dTemp50%/dt decay, and dTemp75%/dt decay (cooling rate measured at 50% and 75% of amplitude decay, respectively). Water spray irrigation significantly reduced T47 (1.37+/-0.29 seconds vs 19.97+/-3.06 seconds, P<0.0001), T50% (3.04+/-0.34 seconds vs 27.37+/-2.56 seconds, P<0.0001), and T75% (5.71+/-0.57 seconds vs 57.61+/-5.47 seconds, P<0.0001). Water spray irrigation also increased cooling capacity ninefold: dTemp50%/dt decay (4.14+/-0.61 degrees C/s vs 0.48+/-0.06 degrees C/s, P<0.0001), and dTemp50%/dt decay (1.70+/-0.29 degrees C/s vs 0.19+/-0.03 degrees C/s, P<0.0001). The continuous use of water spray adjacent to the abutment following the cessation of implant preparation might prove beneficial for rapid cooling of the implant.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heat production during prosthetic preparation of a one-piece dental implant.

PURPOSE Preparation of a one-piece dental implant abutment is often needed to achieve a proper emergence profile for a definitive restoration. However, this procedure may compromise osseointegration through the production of heat. The aim of this study was to measure heat production during implant abutment preparation with different volumes of water irrigation using a one-piece implant system. ...

متن کامل

Restoration of divergent implants with a 2-piece screw-retained fixed, complete dental implant prostheses.

Restoring a severely resorbed maxilla is challenging because of poor bone quality and the resorptive pattern that follows tooth loss. When bone augmentation is not possible, implants are placed in suboptimal positions, making the prosthetic rehabilitation more complex. This report presents the steps used to rehabilitate a severely resorbed maxilla with divergent implants, using an implant-suppo...

متن کامل

Principles of Overdenture on One-piece Narrow Dental Implants in Patients with Different Patterns of Mandibular Ridge Resorption

PRINCIPLES OF OVERDENTURE ON ONE-PIECE NARROW DENTAL IMPLANTS IN PATIENTS WITH DIFFERENT PATTERNS OF MANDIBULAR RIDGE RESORPTION (Abstract). Aim: To highlight the particularities of mandibular overdenture on one-piece narrow dental implants in patients with two frequent and high-difficulty clinical situations, namely flat alveolar ridge (also known as severe ridge resorption, when mainly vertic...

متن کامل

POJ Dental Oral Care

Copyright: © 2017 Minoru Sanda, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Abstract Sputtered hydroxyapatite coated implant has investigated as an implant with novel surface coating for dental impl...

متن کامل

A microstrain comparison of passively fitting screw-retained and cemented titanium frameworks.

STATEMENT OF PROBLEM An imprecise fit between frameworks and supporting dental implants in loaded protocols increases the strain transferred to the periimplant bone, which may impair healing or generate microgaps. PURPOSE The purpose of this study was to investigate the microstrain between premachined 1-piece screw-retained frameworks (group STF) and screw-retained frameworks fabricated by ce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of oral implantology

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 2010