Neural response telemetry measures in patients implanted with Nucleus 24.

نویسندگان

  • Mariana Cardoso Guedes
  • Rubens V Brito Neto
  • Maria Valéria S Goffi Gomez
  • Sandra B Giorgi Sant'Anna
  • Cristina G Ornelas Peralta
  • Arthur Menino Castilho
  • Ricardo Ferreira Bento
چکیده

UNLABELLED Cochlear implantation has been recommended for children under 24 months of age. The use of objective measures is needed to help speech processor programming. The electrically evoked compound potential (EAP), which can be assessed by neural response telemetry (NRT), is one of those objective measures. AIM to determine how often the EAP can be recorded by NRT system during surgery and to describe the responses. STUDY DESIGN Clinical with transversal cohort. MATERIAL AND METHOD The impedances and NRT were measured in a group of 17 Nucleus 24 implant users. The responses were analyzed and compared to the etiology, hearing loss duration and electrode array position. RESULTS The EAP was easily recorded in the apical electrodes and, in otosclerosis and meningitis cases the EAP threshold was higher than in the other etiology cases. CONCLUSIONS The NRT can be found in 82% of the cases during surgery. The responses obtained may vary according to etiology and the position of electrodes along the cochlea.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of neural response telemetry measures to objectively set the comfort levels in the Nucleus 24 cochlear implant.

Cochlear implant programming necessitates accurate setting of programming levels, including maximum stimulation levels, of all active electrodes. Frequently, clinical techniques are adequate for setting these levels; however, they are sometimes insufficient (e.g., very young children). In the Nucleus 24, several methods have been suggested for estimation of comfort levels (C levels) from neural...

متن کامل

Perimodiolar electrode position: Effects on thresholds, comfort levels, impedance measurements, and neural response telemetry

OBJECTIVE: This multicenter study describes the effects of perimodiolar electrode position on 50 adult patients (31 with an implanted Nucleus 24 Contour perimodiolar hugging electrode array [Cochlear Limited, Lane Cove, NSW, Australia] and 19 with an implanted straight electrode array) with a severe-to-profound sensorineural hearing loss. MATERIALS AND METHODS: In all patients, intraoperative i...

متن کامل

Neural response telemetry in cochlear implant users.

Programming of multichannel cochlear implants requires subjective responses to a series of sophisticated psychophysical percepts. It is often difficult for cochlear implant patients (especially young prelinguistically deaf children) to provide adequate responses for device fitting. However, the neural response telemetry (NRT) system renders possible the measurement of the compound action potent...

متن کامل

Behavioral Determination of Stimulus Pair Discrimination of Auditory Acoustic and Electrical Stimuli Using a Classical Conditioning and Heart-rate Approach

Acute animal preparations have been used in research prospectively investigating electrode designs and stimulation techniques for integration into neural auditory prostheses, such as auditory brainstem implants and auditory midbrain implants. While acute experiments can give initial insight to the effectiveness of the implant, testing the chronically implanted and awake animals provides the adv...

متن کامل

Evaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant

Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and moni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian journal of otorhinolaryngology

دوره 71 5  شماره 

صفحات  -

تاریخ انتشار 2005