Development of an experimental optoelectronic device to study the amplitude of mandibular movements.

نویسندگان

  • Reinaldo Missaka
  • Lena Katekawa Adachi
  • Regina Tamaki
  • Rosemary Sadami Arai Shinkai
  • Tomie Nakakuki de Campos
  • Oswaldo Horikawa
چکیده

This study aimed to present a wireless mandibular motion tracking device and optoelectronic data acquisition system developed to analyze the real-time spatial motion of the entire mandible during mouth opening and closing with no restriction of any movement. The procedures were divided into three phases: confection of a kinematic arch, dynamic digital video image acquisition, and image processing and analysis by using graphic computation. Four sequences of jaw opening/closing movements were recorded in lateral view: two from the maximum intercuspation (MIC) and the other two from a forced mandibular retruded position. Jaw motion was recorded by a digital video camera and processed as spatial coordinates corresponding to the position variation of the markers in the kinematic arch. The results showed that the method was capable of recording and processing the dynamics of the mandibular movements during jaw opening/closing using pixel-magnitude points. The mandible showed points with less displacement located near the temporomandibular joint during the opening/closing movements from the mandibular retruded position. When the jaw movements were recorded from MIC, these points were located near the mandibular foramen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neck function in rhythmic jaw activities

Neck function in rhythmic jaw activities. Birgitta Häggman Henrikson 2004. Department of Odontology, Clinical Oral Physiology, Umeå University, and Centre for Musculoskeletal Research, Gävle University, Sweden. Previous studies in animals and humans show anatomic and physiological connections between the trigeminal and the cervical regions. This investigation tested the hypothesis of a function...

متن کامل

Kinematics of Mandibular Motion in the Sagittal Plane

Mandibular kinematics has been a constant concern and matter for study for a long time. Of all the mandibular movements the opening-closing movement in the sagittal plane is the most simple to observe and study. Among the various analyzation methods applicable to mandibular kinematics are the following: photographic, photoelectrical, radiographic, cinematographic, cinefluorographic, graphical, ...

متن کامل

A Combined Experimental and Theoretical Study of Optoelectronic and Structural Properties of a New Copolymer Based on Polyvinylcarbazole (PVK) and Poly (3-hexylthiophene) (PHT)

In this paper we report on a combination of experimental and theoretical study of a new copolymer based on carbazole and methylthiophene (Cbz-Mth), in their neutral and oxidized states. We discuss the influence of chain length on conformational and optoelectronic properties with the DFT method. Conformational analysis shows that there are no big changes in the structural parameters of neutral o...

متن کامل

Development of A Head Docking Device for Linac-based Stereotactic Radiosurgery System to be Installed on Neptun 10 PC Linac

Introduction:  Stereotactic  radiosurgery  is  a  technique  for  the  treatment  of  intracranial  lesions  with  highly  collimated  x-ray  beam.  Linac-based  radiosurgery  is  currently  performed  by  two  techniques:  couch or pedestal mounted. In the first technique, a device is required to affix patient's head to a couch  and  moreover  to  translate  it  accurately.  Structure  of  suc...

متن کامل

Evaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant

Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and moni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian oral research

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2008