Measuring gastric volume by dye dilution.

نویسنده

  • A Hurwitz
چکیده

The double sampling method for measuring gastric volumes is analysed mathematically. It is shown to cause magnification of randomly occurring analytical errors in dye concentration. The errors which arise in calculated gastric volume depend on extent of analytical error, concentration of dye initially placed in the stomach, repetition of analysis cycle, and ratio of volume of added dye to gastric volume. By starting with dye-free water and doubling the concentration of dye added in serial volume determinations the error in calculated volume is markedly reduced and no longer increases with successive measurements. These modifications reduce the limitations inherent in the method as originally described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of the residual volume of the ventricle of the dog's heart by two indicator dilution technics.

A dye dilution and an electric conductivity method for measuring end-diastolic volume and stroke volume of the left ventricle are described, and equations for the calculation of stroke volume are given. When dye is injected "instantaneously" into the left ventricle during diastole, the aortic dye concentration-time curve obtained is a step-like curve and not a smooth curve. The ventricle emptie...

متن کامل

Determining gastric contents during general anaesthesia: evaluation of two methods.

Two methods used to measure the volume of gastric contents were evaluated in 24 supine anaesthetized adults. Methods compared were: (1) aspiration of stomach contents through a large, vented, multi-orificed gastric tube, and (2) indirect determination by a dye dilution method using polyethylene glycol (PEG) as the marker. The volumes determined by these methods (Vasp and Vpeg respectively) were...

متن کامل

Estimation of the Residual Volume of the Ventricle of the Dog's Heart by Two Indicator Dilution Technics

A dye dilution and an electric conductivity method for measuring end-diastolic volume and stroke volume of the left ventricle are described, and equations for the calculation of stroke volume are given. When dye is injected "instantaneously" into the left ventricle during diastole, the aortic dye concentration-time curve obtained is a step-like curve and not a smooth curve. The ventricle emptie...

متن کامل

Thermal dilution measurement of pulmonary and systemic blood flow in secundum atrial septal defect, and transposition of great arteries with intact interventricular septum.

The measurement of cardiac output is difficult in infants and children. In them the Fick and dye dilution methods both have distinct disadvantages. The Fick method requires cumbersome equipment, especially for measuring oxygen uptake. The dye dilution method requires the injection of a dye and the placement of an arterial catheter to sample large quantities of blood rapidly; furthermore, it is ...

متن کامل

Comparison of aspiration and scintigraphic techniques for the measurement of gastric emptying rates of liquids in humans.

A comparison was made of two techniques to measure the rate of gastric emptying. A noninvasive scintigraphic technique using a gammacamera and an invasive aspiration technique based on dye dilution were performed simultaneously. Seven healthy male volunteers each consumed two different liquid meals on two separate occasions. Scintigraphic measurements were performed continuously with aspiration...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Gut

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 1981