Poor eight-year survival of cemented zirconia-polyethylene total hip replacements.

نویسندگان

  • J Allain
  • S Le Mouel
  • D Goutallier
  • M C Voisin
چکیده

Between January 1988 and January 1991 we performed 100 consecutive cemented total hip replacements using a zirconia head, a titanium alloy stem and a polyethylene cup. We reviewed 78 of these hips in 61 patients in detail at a mean of 5.8 years (1 to 9). Aseptic loosening was seen in 11 hips (14%). Eight needed revision. In total, 37 cups (47.5%) showed radiolucent lines, all at the cement-bone interface, with 18 (23%) involving all the interface. Of the 78 femoral implants, 17 (21.7%) showed radiolucent lines, and two, which had a complete line of more than 1 mm thick, definite endocortical osteolyses. There was also an abnormally high incidence of osteolysis of more than 2 mm at the calcar. Survivorship analysis showed that only 63% were in situ at eight years. These worrying results led us to abandon the use of zirconia heads, since at the same hospital, using the same femoral stem, cement and polyethylene cup, but with alumina femoral heads, the survival rate was 93% at nine years. We discuss the possible reasons for the poor performance of zirconia ceramic.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Results of 3,668 primary total hip replacements

BACKGROUND AND PURPOSE In a previous study based on the Finnish Arthroplasty Register, the survival of cementless stems was better than that of cemented stems in younger patients. However, the survival of cementless cups was poor due to osteolysis. In the present study, we analyzed population-based survival rates of the cemented and cementless total hip replacements in patients under the age of...

متن کامل

Cementless total hip arthroplasty for primary osteoarthritis in patients aged 55 years and older

BACKGROUND Cemented total hip arthroplasty has been the treatment of choice for elderly patients with osteoarthritis. We analyzed survival rates of the most common cementless designs used in this age group in Finland. PATIENTS AND METHODS Inclusion criteria permitted 10,310 replacements (8 designs) performed in patients aged 55 years or older to be selected for evaluation. The risk of revisio...

متن کامل

Ceramic-ceramic and metal-polyethylene total hip replacements: comparison of pseudomembranes after loosening.

We made a semiquantitative study of the comparative histology of pseudomembranes from 12 loose cemented ceramic-ceramic and 18 metal-polyethylene total hip replacements. We found no significant difference in cellular reaction between the two groups, but there was a major difference in the origin of the particulate debris. In the metal-polyethylene group, polyethylene of articular origin was pre...

متن کامل

Mortality and implant revision rates of hip arthroplasty in patients with osteoarthritis: registry based cohort study

OBJECTIVES To examine mortality and revision rates among patients with osteoarthritis undergoing hip arthroplasty and to compare these rates between patients undergoing cemented or uncemented procedures and to compare outcomes between men undergoing stemmed total hip replacements and Birmingham hip resurfacing. DESIGN Cohort study. SETTING National Joint Registry. POPULATION About 275,000...

متن کامل

Evaluation of Hylamer-zirconia hip arthroplasty in patients less than 50 years of age.

The purpose of this prospective study was to determine the clinical outcomes of patients who had total hip arthroplasties with a zirconia (Zr) - Hylamer pairing. Fifty-eight consecutive cemented total hip arthroplasties with a Hylamer cup and 22.25 mm Zr head were examined for component wear and failure. The SF-36 and Mayo hip score were used to evaluate patient outcome. Regression and Kaplan M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 81 5  شماره 

صفحات  -

تاریخ انتشار 1999