Renal artery duplex ultrasound criteria for the detection of significant in-stent restenosis.

نویسندگان

  • Ian Del Conde
  • Ira D Galin
  • Biana Trost
  • Jeanwan Kang
  • Robert Lookstein
  • Mark Woodward
  • Susan Gustavson
  • Richard P Cambria
  • Michael R Jaff
  • Jeffrey W Olin
چکیده

OBJECTIVES To define velocity criteria by ultrasonography for the detection of hemodynamically significant (>60%) renal artery in-stent restenosis (ISR). BACKGROUND The restenosis rate after renal artery stenting ranges between 10% and 20%. While duplex ultrasound criteria have been validated for native renal artery stenosis, there are no uniformly accepted validated criteria for stented renal arteries. METHODS Vascular laboratory databases from two academic medical centers were retrospectively reviewed for patients who underwent renal artery stenting followed by duplex ultrasound evaluation and angiography (CT angiography or catheter angiography) as the gold standard. RESULTS A cohort of 132 stented renal arteries that had angiographic comparisons was analyzed. Eighty-eight renal arteries demonstrated 0-59% stenosis while 44 renal arteries revealed 60-99% stenosis by angiography. Both the mean peak systolic velocity (PSV) and the renal artery-to-aortic ratio (RAR) were significantly higher in renal arteries with 60-99% restenosis compared with those with 0-59% restenosis (PSV: 382 cm/sec ± 128 vs. 129 cm/sec ± 62, P<0.001; RAR: 5.3 ± 2.4 vs. 2.1 ± 1.0, P <0.001). The optimal PSV and RAR cutoffs for detecting 60-99% ISR were calculated by receiver operator characteristics curve analysis. The velocity criteria that are associated with these results will be discussed. CONCLUSION Duplex ultrasonography is an accurate technique to identify significant restenosis in stented renal arteries. The PSV and RAR cutoffs for detecting renal artery ISR are higher than those in native, unstented renal arteries. A normal duplex ultrasound after renal artery stenting virtually excludes significant restenosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

گزارش یک مورد آنژیوپلاستی و Stent گذاری موفق در درمان تنگی

    Introduction: Renal transplantation has established itself as the treatment of choice for the majority of patients with End stage renal failure(ESRF). Arterial stenosis is the most common vascular complication after kidney transplantation, occurring in approximately 4%-25% of transplant recipients. Case Report: The patient is a 68 year old man with ESRF due to Poly cystic kidney disease(PCK...

متن کامل

Positionally dependent renal artery restenosis.

A 63-year-old woman with extensive atherosclerotic vascular disease, including long-standing renal artery stenosis, was evaluated for newly uncontrolled hypertension with frequent headaches despite the use of 4 antihypertensive agents. Her blood pressure had been well controlled previously. She had a remote history of right renal artery occlusion and had undergone left renal artery stenting 9 y...

متن کامل

Carotid duplex ultrasound velocity measurements versus intravascular ultrasound in detecting carotid in-stent restenosis.

BACKGROUND Duplex ultrasonography criteria for assessing the severity of carotid artery (CA) in-stent restenosis are not well established. METHODS AND RESULTS We analyzed 39 patients (40 CAs) who underwent CA stenting with baseline and 6-month follow-up carotid duplex ultrasonography and intravascular ultrasound. Intravascular ultrasound measurements included minimum luminal diameter, percent...

متن کامل

Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study

BACKGROUND Carotid angioplasty with stenting is a relatively new, increasingly used, less-invasive treatment for the treatment of symptomatic carotid artery stenosis. It is being evaluated in ongoing and nearly finished randomized trials. An important factor in the evaluation of stents is the occurrence of in-stent restenosis. An un-stented carotid artery is likely to have a more elastic vessel...

متن کامل

Shrinkage of the distal renal artery 1 year after stent placement as evidenced with serial intravascular ultrasound.

The objective of this study was to determine the quantitative intravascular ultrasound (IVUS) and angiographic changes that occur during 1 year follow-up after renal artery stent placement, given that restenosis continues to be a limitation of renal artery stent placement. 38 consecutive patients with symptomatic renal artery stenosis treated with Palmaz stent placement were studied prospective...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions

دوره 83 4  شماره 

صفحات  -

تاریخ انتشار 2014