-H2AX Foci as a Biomarker for Patient X-Ray Exposure in Pediatric Cardiac Catheterization
نویسندگان
چکیده
Background—A better knowledge of patient x-ray dose and the associated radiation risk in pediatric interventional cardiology is warranted in view of the extensive use of x-rays and the higher radiosensitivity of children. In the present study, -H2AX foci were used as a biomarker for radiation-induced effects. Patient-specific dose was assessed and radiation risks were estimated according to the linear-no-threshold model, commonly used in radiation protection, and the -H2AX foci data. Methods and Results—In 49 pediatric patients (median age, 0.75 years) with congenital heart disease who underwent cardiac catheterization procedures, blood samples were taken before and shortly after the procedure. -H2AX foci were determined in peripheral blood T lymphocytes. In each patient, a net increase in -H2AX foci, representing DNA double-strand breaks induced by interventional x-rays, was observed. In addition, a patient-specific Monte Carlo simulation of the procedure was performed, resulting in individual blood, organ, and tissue doses. Plotting of -H2AX foci versus blood dose indicated a low-dose hypersensitivity. Median effective doses calculated according to the International Commission on Radiological Protection 60 and 103 publications are 5.6 and 6.4 mSv, respectively. The lifetime-attributable risk of cancer mortality was calculated from the linear-no-threshold model and the -H2AX foci data. This resulted in lifetime-attributable risk values of 1 per thousand and 4 per thousand, respectively, for the patient population under study. Conclusions— -H2AX foci as a biomarker for DNA damage indicate that radiation risk estimates according to the linear-no-threshold hypothesis are possibly underestimates. Great care should be taken to minimize and optimize patient radiation exposure. (Circulation. 2009;120:1903-1909.)
منابع مشابه
Evaluating Gamma-H2AX Expression as a Biomarker of DNA Damage after X-ray in Angiography Patients
Objective: Coronary heart disease (CHD) is one of the most common diseases. Coronary angiography (CAG) is an important apparatus used to diagnose and treat this disease. Since angiography is performed through exposure to ionizing radiation, it can cause harmful effects induced by double-stranded breaks in DNA which is potentially life-threatening damage. The aim of the present study is to inves...
متن کاملEffective Dose of Radiation in Diagnostic and Interventional Cardiac Angiography among Pediatrics and Adolescents in Hospitals of Shiraz University of Medical Sciences versus Other Radiology Devices
Background: Cardiac catheterization and angiography are diagnostic and therapeutic imaging modalities that produce the highest X-ray radiation, which might impose lifelong risks to patients. This study aimed to evaluate radiation burden among children and adolescents with congenital heart diseases, who underwent cardiac catheterization and angiography. Then the results were compared with other ...
متن کاملInfluence of Different Antioxidants on X-Ray Induced DNA Double-Strand Breaks (DSBs) Using γ-H2AX Immunofluorescence Microscopy in a Preliminary Study
BACKGROUND Radiation exposure occurs in X-ray guided interventional procedures or computed tomography (CT) and γ-H2AX-foci are recognized to represent DNA double-strand breaks (DSBs) as a biomarker for radiation induced damage. Antioxidants may reduce the induction of γ-H2AX-foci by binding free radicals. The aim of this study was to establish a dose-effect relationship and a time-effect relati...
متن کاملγ-H2AX as a protein biomarker for radiation exposure response in ductal carcinoma breast tumors: Experimental evidence and literature review
Background: H2AX is a histone variant that is systematically found and ubiquitously distributed throughout the genome. DNA double-strand breaks (DSBs) induce phosphorylation of H2AX at serine 139 (γH2AX), an immunocytochemical assay with antibodies recognizing γH2AX has become the gold standard for the detection of DSBs. The importance of this assay to investigate different individu...
متن کاملSurvey of a Practical Approach to Central Venous Catheterization in Pediatric Patients
Background Central venous catheter (CVC) is used for measuring hemodynamic variables, transfusion of blood, fluids and medications when peripheral vascular lack sufficiency. Unfortunately CVC is associated with many complications ranging from anxiety and discomfort for the patient to severe mechanical side effects such as arterial lacerations, pleural and pericardial injury as well as infection...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009