Transient stability augmentation of PV/DFIG/SG-based hybrid power system by parallel-resonance bridge fault current limiter

نویسندگان

  • Md. Kamal Hossain
  • Mohd. Hasan Ali
چکیده

This paper proposes a parallel-resonance bridge type fault current limiter (PRBFCL) to augment the transient stability of a hybrid power system consisting of a photovoltaic (PV) power generation source, a doubly-fed induction generator (DFIG)-based wind energy system, and a synchronous generator (SG). The PRBFCL is designed such a way that it can provide sufficient damping characteristics to the studied power system. The effectiveness of the proposed PRBFCL in improving the transient stability and enhancing the dynamic performance of the hybrid power system is verified by applying both balanced and unbalanced faults in the power network. Also, its performance is compared with that of the bridge type fault current limiter (BFCL) and the fault ride through (FRT) schemes, i.e. FRT schemes of PV, DFIG, and with the AVR and governor of synchronous generator (SG). Some indexes are used to quantify the system performance. Simulation results obtained from the Matlab/Simulink software show that the proposed PRBFCL is effective in maintaining stable operation of the PV, wind generator, and synchronous generator during the grid fault. Moreover, the performance of the PRBFCL is better than that of the BFCL and the FRT methods in every aspect. © 2015 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm

Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...

متن کامل

Transient stability enhancement of DFIG based 10 MW wind farm by using of new inductive bridge type fault current limiter

Due to numerous advantages of the doubly-fed induction generator (DFIG), the application of DFIG based wind generator (WG) is increasing very rapidly. However, the transient stability is one of the major concerns of the DFIG based wind generator. Therefore to accomplish this goal, in this paper, an existing non-linear controller based new inductive bridge type fault current limiter (NC-NIBFCL) ...

متن کامل

Selection of Resistive and Inductive Superconductor Fault Current Limiters Location Considering System Transient Stability

Superconductor fault current limiter (SFCL) is an effective device to suppress high fault currents. This paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view.  Appropriate location and type of the limiters in a HV substation is selected by a qualitative approach based on the equal area criterion. Study system is simulated by...

متن کامل

The Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System

In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016