Power quality improvement in DFIG system using D-STATCOM

نویسندگان

  • Shailendra Kumar
  • Preeti Jain
چکیده

The wind energy conversion system (WECS) differs from other power systems. It is clean and pollution free. But the output of wind power plant is fluctuated in nature. It depends on the wind speed. The nature of wind is variable. The variable wind generates fluctuated power. Fluctuated output is the major problem of wind power plant. This problem can be solved by using convertor units. The second problem of wind power plant is different types of fault occurring in wind power plants, like line fault and grid fault etc. This paper discusses the fault in wind power plant or fault analysis in DFIG system, using D-STATCOM. The DSATCOM is a shunt device which is used to solve fault problem in distribution system. These papers discuss the analysis and output characteristics of doubly feed induction generator (DFIG) due to the normal and abnormal condition. This paper has presented the power quality problems such as voltage dips, swells and interruptions, and mitigation techniques of custom power electronic device D-STATCOM. This device is used for controlling the voltage fluctuation, flicker reduction and to maintain voltage stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of STATCOM and CROWBAR for Transient Stability Improvement and Performance Enhancement for A Wind Turbine Based Doubly Fed Induction Generator

This paper presents a robust control of Doubly Fed Induction Generator (DFIG) wind turbine in a sample power system. DFIG consists of a common induction generator with slip ring and a partial scale power electronic converter. Indirect fieldoriented controller is applied to rotor side converter for active power control and voltage regulation of wind turbine. On grid side PQ control scheme is app...

متن کامل

Fault Ride through Capability Improvement of Wind Turbine Based DFIG Considering an Optimized Crowbar Along with STATCOM under Grid Fault Condition

Grid disturbances, especially grid faults, have very unfavorable effect on the performance of wind turbine based Doubly Fed Induction Generator (DFIG). In this study active and reactive powers control of DFIG with STATCOM has been carried out to improve Fault Ride Through (FRT) capability of a wind turbine. In order to excel improvement of the DFIG behavior under grid fault disturbances, an opt...

متن کامل

Stability Enhancement of Dfig Wind Turbines by Parameters Tuning of Shunt Connected Facts Devices Using Itae Index

In recent years, the doubly fed induction generators (DFIGs) are used in modern wind power plants. These generators have a large impact on the stability of power system. In this paper, we examine the stability of DFIG wind turbines with static synchronous compensator (STATCOM). Optimal tuning of STATCOM control Parameters is very important in order to proper Performance of STATCOM as a stabiliz...

متن کامل

Stability Improvement of a Hybrid DFIG-Based and PMSG- Based Offshore Wind Farm fed to a SG-Based Power System Using a STATCOM

This paper presents the stability-improvement results of a synchronous generator (SG)-based one-machine infinite-bus (OMIB) system with a hybrid doubly-fed induction generator (DFIG)-based and permanent-magnet synchronous generator (PMSG)-based offshore wind farm (OWF) using a static synchronous compensator (STATCOM). The operating performance of the studied PMSG-based OWF is simulated by an eq...

متن کامل

Improving the performance of wind turbine equipped with DFIG using STATCOM based on input-output feedback linearization controller

Using the FACTS controllers, such as static synchronous compensator (STATCOM), as it provides continuous reactive power, in the grid including wind turbine (WT) equipped with doubly fed induction generator, for improving voltage profile (under normal circumstances) and providing a transition ability from inductor generator transition state has been proposed. In this paper, in order to contr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013