Repeatability and agreement in the measurement of horizontal fusional vergences.
نویسندگان
چکیده
PURPOSE This study was designed to determine the repeatability of fusional vergence ranges measured using the rotary prisms in the phoropter and in free space using the prism bar. The level of agreement between the two methods was also investigated. METHODS In two separate sessions, negative and positive fusional vergence ranges (NFV and PFV, respectively) were measured at distance and near in 61 young adults (mean age 19.74, S.D. 2.5 years) who were unfamiliar with the methods used. Base-in and base-out blur, break and recovery points were sequentially determined. Both sets of measurements were obtained by the same examiner. At each distance, NFV was determined first and then PFV. The repeatability of the tests and agreement between measurements made with the phoropter rotary prisms and the prism bar were estimated by the Bland and Altman method. RESULTS For both the phoropter rotary prisms and prism bar, NFV measurements showed better repeatability than PFV at both near and distance. Mean differences recorded for the NFV break and recovery points were non-significant (under 0.5Delta), while those observed for PFV were generally greater than 2Delta. When agreement between the two tests was assessed, it was found that break points were higher when determined using the phoropter rotary prisms, while recovery points were generally higher for the prism bar method. In clinical terms, according to the expected values of the NFV and PFV, agreement between the two techniques can be described as fair, because although mean differences were never greater than 5.5Delta, 95% agreement intervals were as wide as +/-8.00Delta for NFV and +/-13.19Delta for PFV. CONCLUSIONS The two methods used to measure fusional vergences showed fairly good inter-session repeatability for measuring NFV but repeatability was reduced for PFV measurements. The level of agreement observed between the two methods was such that their interchangeable use in clinical practice is not recommended.
منابع مشابه
Torsional fusional vergences and assessment of cyclodeviation by synoptophore method.
Two special slides, one in front of one eye and one in front of the other eye, were placed in the housings of a synoptophore. The slides were originally designed for the diagnosis and measurement of cyclodeviation, but they were utilised in this study for the measurement of torsional fusional vergence. This was measured by rotating one of the housings of the synoptophore and noting the point of...
متن کاملEvaluation of ocular accommodation, convergence and fusional vergence changes during Ramadan
Purpose: There are a few researches regarding the effects of Islamic fasting on visual system. The aim of this study was to investigate the effects of Ramadan fasting on the amplitude of accommodation (AA), near point of convergence (NPC), positive and negative fusional vergences (PFV and NFV, respectively) in visually healthy fasters. Methods: AA, NPC, PFV and NFV at far (6m) and near (40cm) w...
متن کاملVertical fusional vergence: the key to dissociated vertical deviation.
OBJECTIVES To test the previous findings of Enright that disparity-induced vertical vergence is mediated primarily by the oblique muscles, and to relate this normal eye movement pattern to the eye movement pattern seen in subjects with dissociated vertical deviation. METHODS Sixteen normal volunteers underwent 55 measurements of the cycloversion associated with prism-induced vertical vergence...
متن کاملVariability of fusion vergence measurements in heterophoria Fusion vergence measurements
Purpose: The aims of this study were to compare fusional vergence measurements between orthophoria, esophoria and exophoria, and to determine the strength of correlations between fusional convergence and divergence and angle of deviation. Methods and materials: A cross-sectional study was performed in children with best-corrected visual acuity of 0.0 LogMAR in either eye, compensated heterophor...
متن کاملComparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects
Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects. Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians
دوره 28 5 شماره
صفحات -
تاریخ انتشار 2008