Mixed venous oxygen saturation in relation to cardiac output in myocardial infarction.

نویسندگان

  • A L Muir
  • B J Kirby
  • A J King
  • H C Miller
چکیده

Mixed venous oxygen saturations derived from measurement of mixed venous oxygen tension were compared with dye dilution cardiac output determinations in 26 patients with acute myocardial infarction. Mixed venous oxygen saturation was greatly reduced in patients with shock or failure complicating myocardial infarction. The level of oxygen saturation correlated with cardiac output determinations. The measurement of mixed venous oxygen saturation, which is relatively simple and does not require elaborate equipment, should be an important aid to the rational treatment of patients with low output states complicating acute myocardial infarction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Overshoot in mixed venous oxygen saturation during recovery from supine bicycle exercise in patients with recent myocardial infarction.

During recovery from dynamic exercise, systemic oxygen extraction rapidly decreases below the resting level in patients with heart failure, which leads to a subsequent increase in mixed venous oxygen saturation (SvO2) above its resting value (postexercise SvO2 overshoot). To evaluate the pathophysiologic basis of this phenomenon, postexercise SvO2 overshoot was evaluated in relation to hemodyna...

متن کامل

The Hemodynamic Effects of Drugs on Myocardial Oxygen Use

The circulatory responses to high equinalgesic doses of morphine are compared with those of pethidin. The decrease in mean arterial blood pressure in case of morphine was 28p.c., with a paralleled and identical de­crease in total peripheral resistance and no negative inotropic effects.  Pethidine decreased blood pressure 54p.c., as a result of peripheral vasodilation of 46p.c. and a sharp drop...

متن کامل

Influence of cardiac output on the correlation between mixed venous and central venous oxygen saturation.

The influence of cardiac output on the correlation between central venous oxygen saturation and mixed venous oxygen saturation was assessed in 51 patients who had both a pulmonary artery catheter and separate central venous catheter in situ. Seventy-six paired samples were taken from the catheters and oxygen saturation measured immediately in a Ciba Corning 2500 Co-oximeter. Cardiac output was ...

متن کامل

Disturbance of pulmonary gas exchange in patients with right ventricular infarction.

To evaluate the difference in pulmonary gas exchange in patients with and without right ventricular infarction, 147 consecutive patients with their first inferior wall Q-wave acute myocardial infarction were studied. Thirty-nine patients (group 1) had electrocardiographic evidence of right ventricular infarction and it was absent in 108 patients (group 2). A significantly wider alveolar arteria...

متن کامل

Correlation of mixed venous and central venous oxygen saturation and its relation to cardiac index

Background and Aim: The clinical applicability of substitution of central venous oxygen saturation for mixed venous oxygen saturations in monitoring global tissue hypoxia is still a matter of controversy. Hence aim of the study is comparison of paired samples of mixed venous and central venous oxygen saturation and comparison in relation to cardiac index in varying hemodynamic conditio s. Mater...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British medical journal

دوره 4 5730  شماره 

صفحات  -

تاریخ انتشار 1970