Equiblur zones at the fovea and near retinal periphery

نویسندگان

  • Bin Wang
  • Kenneth J. Ciuffreda
  • Trevor Irish
چکیده

Knowledge regarding successive blur discrimination thresholds (i.e., equiblur zones) in depth and across the near retinal periphery, and their relation to blur detection (i.e., depth-of-focus), remains unknown. The blur detection threshold and four successive blur discrimination thresholds were measured psychophysically at the fovea, as well as at retinal eccentricities of 0.25 degrees , 2 degrees , 4 degrees , and 8 degrees . A Badal optometer system was used to assess blur sensitivity monocularly in five visually normal young adults with cycloplegia. The foveal test stimulus consisted of a small irregularly shaped black form, and the peripheral test stimulus consisted of high contrast circular apertures of different radii. Both the group mean blur detection and successive blur discrimination thresholds progressively increased with retinal eccentricity. At retinal eccentricities of 0 degrees , 0.25 degrees , 2 degrees , 4 degrees , and 8 degrees , the group mean blur detection thresholds were 0.53+/-0.06 D, 0.59+/-0.10 D, 0.93+/-0.11 D, 0.98+/-0.16D, and 1.25+/-0.25 D, while the average values of the group mean blur discrimination thresholds across the steps were 0.29+/-0.01 D, 0.37+/-0.01 D, 0.48+/-0.00 D, 0.51+/-0.01 D, and 0.72+/-0.02 D, respectively. At each retinal eccentricity, the blur discrimination thresholds were similar to each other, and they were approximately 60% of the blur detection threshold magnitude. These findings provide a conceptual representation of blur perception throughout the central visual field. Possible mechanisms are proposed for the decreased blur sensitivity in the near retinal periphery, as well as for the difference between the blur detection and blur discrimination thresholds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Depth-of-focus of the human eye in the near retinal periphery

Although the depth-of-focus in the foveal region has been well investigated, knowledge regarding the effect of retinal eccentricity on blur detection and sensitivity is limited. In the present study, the depth-of-focus at the fovea and in the near retinal periphery (0 degrees -8 degrees ) was assessed psychophysically in 7 human subjects using a 5 mm artificial pupil with accommodation paralyze...

متن کامل

Colour appearance and compensation in the near periphery

The spectral sensitivity of the visual system varies markedly between the fovea and surrounding periphery owing in part to the rapid fall in macular pigment density with eccentricity. We examined how colour appearance changes between the fovea and near periphery (8 degrees) by measuring achromatic loci and the loci of unique and binary hues. Chosen colours remained much more similar at the two ...

متن کامل

Optical, receptoral, and retinal constraints on foveal and peripheral vision in the human neonate

We examined the properties of the foveal, parafoveal, and near peripheral cone lattice in human neonates. To estimate the ability of these lattices to transmit the information used in contrast sensitivity and visual acuity tasks, we constructed ideal-observer models with the optics and photoreceptors of the neonatal eye at retinal eccentricities of 0, 5, and 10 degrees. For ideal-observer model...

متن کامل

Brightness as a function of retinal locus

Brightness functions were determined for the dark-adapted fovea and periphery. In one series of experiments, observers matched numbers to the brightness of a 1° white target at various intensities, presented half the time to the fovea, the other half to one of five peripheral loci: 5°, 12°, 20°, 35°, and (;0°. In a second series, observers matched the brightness of a 1°white target in the fovea...

متن کامل

Binocular recognition summation in the peripheral visual field: contrast and orientation dependence

Spatial frequency thresholds for recognition were measured for binocular and monocular viewing conditions at two contrast levels (95% and 7%). Measurements were obtained at the fovea and at four different eccentric retinal locations. Each eccentric retinal location was 8 degrees from the fovea, one on the horizontal axis (180 degrees ), and the other three in the superior field on retinal axes ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 46  شماره 

صفحات  -

تاریخ انتشار 2006