Short report letter: Three-dimensional printed anatomical models in scaphoid surgery

نویسندگان

  • Paul W. L. ten Berg
  • Johannes G. G. Dobbe
  • Geert J. Streekstra
چکیده

When undertaking surgery for nonunion of scaphoid fractures, appreciation of the three dimensional (3D) anatomy and hence accurate restoration of the original shape of the bone is difficult. Computerised tomography (CT) is regularly used to evaluate scaphoid nonunions slice by slice before surgery. As a potential aid for surgical planning, we have developed a method for producing 3D printed anatomical models of the un-united scaphoid and the intact scaphoid based on the contralateral side. Bilateral CT scans of the wrist were obtained. Virtual 3D CT models of the proximal and distal nonunion fragments and the intact scaphoid, mirrored to the injured side, were created using custom image segmentation software (Dobbe et al., 2011) (Figure 1). Printing was performed using a Blueprinter M2 (Blueprinter , Copenhagen, Denmark) based on thermoplastic powder with 100mm resolution. We evaluated the use of the 3D models in an experimental bench study on palmar plate fixation of the scaphoid, which has been recommended for treatment of some nonunions (Dodds and Halim, 2016). Synthetic printed models were produced from eight patient cases with unilateral scaphoid nonunion with palmar bone loss. Three operators simulated corrective surgery on the synthetic bone

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter-observer agreement between 2-dimensional CT versus 3-dimensional I-Space model in the Diagnosis of Occult Scaphoid Fractures

  Background: The I-Space is a radiological imaging system in which Computed Tomography (CT)-scans can be evaluated as a three dimensional hologram. The aim of this study is to analyze the value of virtual reality (I-Space) in diagnosing acute occult scaphoid fractures.   Methods: A convenient cohort of 24 patients with a CT-scan from prior studies, without a scaphoid fracture on radiograph, ye...

متن کامل

The anatomy of acute scaphoid fractures: a three-dimensional analysis of patterns.

Various classifications of scaphoid fractures have been based on plain radiography, but there are difficulties in defining the actual fracture line without an appreciation of the three-dimensional anatomy. Radiological fracture lines were therefore mapped on transparent methylmethacrylate models of the bone. An analysis of 91 acute fractures showed that 11 were apparently incomplete. The other ...

متن کامل

Unusual Complete Isolated Scaphoid Dislocation, Report of a Case

Isolated scaphoid dislocations are extremely rare injuries and are commonly associated with significant ligamentousdisruptions. A dorsiflexion-supination force upon the hand is considered as the most common mechanism of injury.Different treatment options have been proposed for the management of this uncommon entity, ranging from conservativetreatment with closed reduction and casting to a wide ...

متن کامل

Three-Dimensional Assessment of Bilateral Symmetry of the Scaphoid: An Anatomic Study

Preoperative 3D CT imaging techniques provide displacement analysis of the distal scaphoid fragment in 3D space, using the matched opposite scaphoid as reference. Its accuracy depends on the presence of anatomical bilateral symmetry, which has not been investigated yet using similar techniques. Our purpose was to investigate symmetry by comparing the relative positions of distal and proximal po...

متن کامل

Closed K-wire Fixation for the Treatment of Perilunate Dislocation and Trans-Scaphoid Perilunate Fracture Dislocations without Ligamentous Repair: Short Term Follow-Up

Background: The purpose of this study was to evaluate the treatment outcomes of perilunate dislocations (PLDs) andtransscaphoid perilunate fracture dislocations (TSPLDs) treated with operative volar approach without ligament repairor reconstruction.Methods: A total of seven patients (10 hands) were studied during 2017-2018. We fixed scaphoid fractures thorougha volar app...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 43  شماره 

صفحات  -

تاریخ انتشار 2018