Accuracy and optimal timing of activity measurements in estimating the absorbed dose of radioiodine in the treatment of Graves' disease.

نویسندگان

  • S Merrill
  • J Horowitz
  • A C Traino
  • S R Chipkin
  • C V Hollot
  • Y Chait
چکیده

Calculation of the therapeutic activity of radioiodine (131)I for individualized dosimetry in the treatment of Graves' disease requires an accurate estimate of the thyroid absorbed radiation dose based on a tracer activity administration of (131)I. Common approaches (Marinelli-Quimby formula, MIRD algorithm) use, respectively, the effective half-life of radioiodine in the thyroid and the time-integrated activity. Many physicians perform one, two, or at most three tracer dose activity measurements at various times and calculate the required therapeutic activity by ad hoc methods. In this paper, we study the accuracy of estimates of four 'target variables': time-integrated activity coefficient, time of maximum activity, maximum activity, and effective half-life in the gland. Clinical data from 41 patients who underwent (131)I therapy for Graves' disease at the University Hospital in Pisa, Italy, are used for analysis. The radioiodine kinetics are described using a nonlinear mixed-effects model. The distributions of the target variables in the patient population are characterized. Using minimum root mean squared error as the criterion, optimal 1-, 2-, and 3-point sampling schedules are determined for estimation of the target variables, and probabilistic bounds are given for the errors under the optimal times. An algorithm is developed for computing the optimal 1-, 2-, and 3-point sampling schedules for the target variables. This algorithm is implemented in a freely available software tool. Taking into consideration (131)I effective half-life in the thyroid and measurement noise, the optimal 1-point time for time-integrated activity coefficient is a measurement 1 week following the tracer dose. Additional measurements give only a slight improvement in accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radioiodine (131-I) treatment for Graves’ disease: Geant4 Monte Carlo simulation for patient personalized dose estimation

Background: Reliable estimation of radiation-absorbed dose is necessary to evaluate the benefits and the risks of radiopharmaceuticals used for diagnostic or therapeutic purposes in nuclear medicine. Materiel and Methods: This study included 47 patients treated with iodine-131 for Graves’ disease. A comparative study between Geant4 Monte Carlo simulation and MIRD formalism was carried out to ev...

متن کامل

Determination of absorbed dose of organs (thyroid, sternum, cervical vertebra) in thyroid cancer patients following radioiodine therapy

  Introduction: In patients with thyroid carcinoma, radiation absorbed doses of the thyroid and surrounding tissues is important to weigh risk and benefit considerations. In nuclear medicine, the accuracy of absorbed dose of internally distributed radionuclides is estimated by different methods such as MIRD and direct method using TLD. The aim of this study is using T...

متن کامل

Determination of organ doses in radioiodine therapy using medical internal radiation dosimetry (MIRD) method

Background: Radioiodine therapy has proven to be an effective method in the treatment of patients with differentiated thyroid carcinoma after thyroidectomy. The scope of this study is to describe a method to obtain the dose of organs using medical internal radiation dosimetry (MIRD) method. At the end, the results of MIRD calculations were compared with thermoluminescent dosimeter (TLD...

متن کامل

مقایسه نتایج دو روش درمان با I¹³¹ با دوز ثابت 5 میلی کوری و دوز ثابت 10 میلی کوری در درمان بیماری گریوز، بیمارستان شریعتی، 80-1378

Radioiodine therapy is the safest, simplest, least expensive and most effective method for treatment of Graves' disease. Due to difficulties in previous methods for dose determination, fixed dose method of 1-131 is now considered the best practical method for 1-131 therapy in Graves' disease, but there is no consensus on the dose. We compared two routinely recommended fixed doses of 5 and 10 mC...

متن کامل

Estimation of absorbed dose of salivary glands in radioiodine therapy and its reduction using pilocarpine [Persian]

  Introduction:  The use of radioactive iodine (131I) has become an important adjunct to the treatment of thyroid cancer and hyperthyroidism. Salivary gland has the ability to concentrate radioactive iodine under normal circumstances. Salivary gland dysfunction and dry mouth are the common side effectsof high-dose radioiodine therapy. The purposeof this stu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 56 3  شماره 

صفحات  -

تاریخ انتشار 2011