Precision and Casimir Force Measurements in Superfluid Helium and Vacuum with Silicon Nitride Membranes
نویسنده
چکیده
The recent discovery that silicon nitride membranes can be used as extremely high Q mechanical resonators makes possible a number of novel experiments, which include improved long range vacuum Casimir force measurements, and measurments of the properties of liquid helium below the lambda point. It is noted that in the thermal correction to the Casimir force, the phase velocity of the excitations does not enter, with the force per unit area between parallel plates depending only on the temperature and distance between the plates. Thus it appears as possible to measure the phonon analog of the finite temperature Casimir force in liquid helium.
منابع مشابه
Fabricating Nanoscale Aperture Arrays as Superfluid 4He Weak Links
Arrays of nanoscale apertures have been discovered to exhibit the characteristic signatures of so-called Josephson weak links in superfluid helium-4, 4He [1]. These devices can be used to detect quantum phase differences in a matter wave interferometer [2]. Thin (~ 60 nm) silicon nitride membranes were made by photolithography on silicon wafers and several varieties of aperture arrays shot on t...
متن کاملCasimir force and in situ surface potential measurements on nanomembranes.
We present Casimir force measurements in a sphere-plate configuration that consists of a high quality nanomembrane resonator and a millimeter sized gold coated sphere. The nanomembrane is fabricated from stoichiometric silicon nitride metallized with gold. A Kelvin probe method is used in situ to image the surface potentials to minimize the distance-dependent residual force. Resonance-enhanced ...
متن کاملDynamic and Static Pull-in instability of electrostatically actuated nano/micro membranes under the effects of Casimir force and squeezed film damping
In the current study, the effects of Casimir force and squeeze film damping on pull-in instability and dynamic behavior of electrostatically actuated nano and micro electromechanical systems are investigated separately. Linear elastic membrane theory is used to model the static and dynamic behavior of the system for strip, annular and disk geometries. Squeeze film damping is modeled using nonli...
متن کاملSuperfluid Helium-4 Weak Link Experiments with Nanoscale Aperture Arrays
Arrays of nanoscale apertures on thin (~ 60 nm) silicon nitride membranes have been discovered to exhibit the characteristic signatures of so-called Josephson weak links in superfluid helium-4 (4He) [1]. These devices can be used to detect quantum phase differences in a matter wave interferometer made with two weak-links in a loop [2]. We summarize here our recent [3] observation of quantum int...
متن کاملLocal charge transport in two-dimensional PbSe nanocrystal arrays studied by electrostatic force microscopy.
Two-dimensional PbSe nanocrystal arrays on silicon nitride membranes were investigated using electrostatic force microscopy (EFM) and transmission electron microscopy (TEM). Changes in lattice and transport properties upon annealing in a vacuum were revealed. Local charge transport behavior was directly imaged by EFM and correlated to nanopatterns observed with TEM. Charge transport through nan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008