Coronary lumen at six-month follow-up of a new radiopaque Cordis tantalum stent using quantitative angiography and intracoronary ultrasound.
نویسندگان
چکیده
To determine the reliability of geometric (edge-detection) quantitative coronary angiographic analysis (QCA) of restenosis within a new Cordis tantalum stent, QCA and intracoronary ultrasound (ICUS) measurements were compared in both an experimental restenosis model and in the clinical follow-up of patients. In the experimental series, Plexiglas phantom vessels with concentric stenosis channels ranging from 0.75 to 3.0 mm in diameter and with a reference diameter of 3.0 mm were imaged both before and after their insertion in tantalum stents. In the clinical series, the agreement of QCA and ICUS measurements were studied in 23 patients who had undergone coronary implantation of the new tantalum stent and in 23 patients who had undergone balloon angioplasty 6 months previously. The reliability of QCA declined in the presence of the radiopaque stent (accuracy of QCA decreased from -0.07 to -0.12 mm), whereas the reliability of lumen measurements by ICUS was independent of the presence of the radiopaque stent (-0.12 and -0.13 mm). Without the stent, the average minimal luminal diameter (MLD) obtained by QCA of the 1.00 mm Plexiglas vessel was 1.00 +/- 0.01 mm, and the 3.00 mm reference vessel diameter was 2.81 +/- 0.05 mm, providing a 64 +/- 1% diameter stenosis. After introduction of the stent, the average MLD and reference vessel diameter were 0.99 +/- 0.06 and 3.36 +/- 0.17 mm, respectively, providing a diameter stenosis of 71 +/- 2%. ICUS measurements (2.77 mm) of the reference vessel diameter (3.00 mm) were unaffected by the presence of the stent.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Effects of intracoronary beta-radiation therapy after coronary angioplasty: an intravascular ultrasound study.
BACKGROUND Endovascular radiation is emerging as a potential solution for the prevention and treatment of restenosis. Its effects on the morphology of unstented vessels cannot be determined by angiography and therefore require the use of intravascular ultrasound. METHODS AND RESULTS Through a 5F noncentered catheter for delivery of a 90Sr/Y source train, 12, 14, or 16 Gy at 2 mm was delivered...
متن کاملPercutaneous coronary revascularization using a trilayer metal phosphorylcholine-coated zotarolimus-eluting stent.
The ZoMaxx Coronary Stent System elutes the antiproliferative agent zotarolimus via a biocompatible phosphorylcholine polymer loaded onto a novel, thin, stainless steel stent platform containing an 0.0007-inch inner layer of tantalum that enhances fluoroscopic radiopacity. The objective of this single-arm prospective clinical trial was to assess the safety and performance of the ZoMaxx stent fo...
متن کاملIntra Vascular Ultrasound in Coronary Syndromes: an Overview
fHE CONVENTIONAL coronary angiogram provides :letails of the lumen of the coronary arteries. The mgiogram, however, does not provide information of the structure of the intima, media, and adventitia. With intracoronary ultrasound probes, it is possible to directly obtain information not only of the coronary lumen but also of the type of intraluminal structures and to differentiate cholesterol f...
متن کاملPersistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up.
BACKGROUND Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. METHODS AND RESULTS Fifte...
متن کاملChoice of Intracoronary Imaging: When to use Intravascular Ultrasound or Optical Coherence Tomography.
Intracoronary imaging has the capability of accurately measuring vessel and stenosis dimensions, assessing vessel integrity, characterising lesion morphology and guiding optimal percutaneous coronary intervention (PCI). Coronary angiography used to detect and assess coronary stenosis severity has limitations. The 2D nature of fluoroscopic imaging provides lumen profile only and the assessment o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of cardiology
دوره 76 16 شماره
صفحات -
تاریخ انتشار 1995