Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: removing Gibbs ringing effects using optimized radial imaging.
نویسندگان
چکیده
PURPOSE Subendocardial dark-rim artifacts (DRAs) remain a major concern in first-pass perfusion (FPP) myocardial MRI and may lower the diagnostic accuracy for detection of ischemia. A major source of DRAs is the "Gibbs ringing" effect. We propose an optimized radial acquisition strategy aimed at eliminating ringing-induced DRAs in FPP. THEORY AND METHODS By studying the underlying point spread function (PSF), we show that optimized radial sampling with a simple reconstruction method can eliminate the oscillations in the PSF that cause ringing artifacts. We conducted realistic MRI phantom experiments and in vivo studies (n = 12 healthy humans) to evaluate the artifact behavior of the proposed imaging scheme in comparison to a conventional Cartesian imaging protocol. RESULTS Simulations and phantom experiments verified our theoretical expectations. The in vivo studies showed that optimized radial imaging is capable of significantly reducing DRAs in the early myocardial enhancement phase (during which the ringing effect is most prominent and may obscure perfusion defects) while providing similar resolution and image quality compared with conventional Cartesian imaging. CONCLUSION The developed technical framework and results demonstrate that, in comparison to conventional Cartesian techniques, optimized radial imaging with the proposed optimizations significantly reduces the prevalence and spatial extent of DRAs in FPP imaging.
منابع مشابه
Eliminating dark-rim artifacts in first-pass myocardial perfusion imaging
Background We demonstrate that projection imaging significantly reduces the prevalence and spatial extent of subendocardial dark-rim artifacts (DRAs) in first-pass perfusion (FPP) myocardial MR, compared to conventional Cartesian techniques. A major cause of DRAs, which remain a major concern in FPP imaging, is known to be the socalled Gibbs ringing (truncation) phenomenon [1-3]. Radial k-space...
متن کاملSimulation of Motion-Induced Dark-Rim Artifacts for Cartesian and Spiral Pulse Sequences
Introduction: First-pass MR perfusion images may be corrupted by dark-rim artifacts, which are at least in part a consequence of myocardial motion during data acquisition [1]. We have previously shown that the non-linear time-varying displacements of the myocardium resulting from cardiac contraction result in dark-rim artifacts that have a different appearance in images obtained at different ph...
متن کاملVariability of myocardial perfusion dark rim Gibbs artifacts due to sub-pixel shifts
BACKGROUND Gibbs ringing has been shown as a possible source of dark rim artifacts in myocardial perfusion studies. This type of artifact is usually described as transient, lasting a few heart beats, and localised in random segments of the myocardial wall. Dark rim artifacts are known to be unpredictably variable. This article aims to illustrate that a sub-pixel shift, i.e. a small displacement...
متن کاملProjection imaging of myocardial perfusion: minimizing the subendocardial dark-rim artifact
Background Current methods for clinical myocardial perfusion (MP) imaging suffer from image artifacts, specifically the socalled subendocardial dark-rim artifact (DRA) [1-3]. DRAs are especially limiting since they can reduce the sensitivity/specificity of detecting subendocardial MP deficits; hence, eliminating such artifacts remains an active area of research [1]. In this work, we demonstrate...
متن کاملFirst-pass perfusion CMR with reduced dark-rim artifact and instantaneous image reconstruction using optimized cartesian sampling and apodization
Background Subendocardial dark-rim artifact (DRA) continues to be a major issue that limits the diagnostic performance of first pass perfusion (FPP) CMR. Non-Cartesian approaches such as radial or spiral acquisition have been proposed to minimize DRAs. Among these approaches, those that can operate without the need for breath-holding typically require a time-consuming offline image reconstructi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 72 1 شماره
صفحات -
تاریخ انتشار 2014