Clinical observation of atrial threshold monitoring algorithm: a single center experience.
نویسندگان
چکیده
OBJECTIVE To observe the atrial capture management in an atrial threshold monitoring algorithm. By calculating the enabling rate of the atrial threshold monitoring algorithm and comparing atrial thresholds measured automatically and manually, we evaluate its safety, reliability and applicability in clinical practice. METHODS AND RESULTS Data were collected at implant, start of atrial threshold monitoring, visits scheduled 1 month, 2 months and 4 months thereafter, and upon notification of adverse events. Atrial threshold monitoring algorithm was enabled in 94 patients, while in 38 not, indicating an enabling rate of 71.2%. Causes of the unsuccessful attempts to enable automatic atrial threshold include tachycardia (2, 5.3%), and atrial safety margin not met (36, 94.7%). A total of 88 pairs of atrial thresholds measured automatically and manually were gained. The auto threshold was 0.528 ± 0.270 V, and the manual threshold was 0.580 ± 0.223 V. There is a strict correlation between the automatic measurements and those conducted manually by the physician with a P < 0.05. No significant differences were observed during the 1-month, 2-month and 4-month follow-up. CONCLUSION Atrial threshold monitoring algorithm is safe, reliable and applicable over time. Atrial threshold monitoring tested atrial threshold was demonstrated to be clinically equivalent to the manual atrial threshold test. The addition of atrial threshold monitoring will benefit the patients by reducing energy cost and enhancing pacemaker safety.
منابع مشابه
Cardiac Myxoma, a Rare But Most Common Encountered Cardiac Tumor: A Single Center Experience
Introduction: Cardiac myxoma is a benign and rare tumor, which can present with a grim phenomenon if the presentation is late or the diagnosis and surgery are delayed. The purpose of this study was to share our institutional experience of cardiac myxoma. Material and Methods: This retrospective study was conducted to evaluate patients undergoing procedures at a single tertiary care centre for t...
متن کاملThe effects of Vitamin C on Inflammatory Markers and Atrial Fibrillation in Patients Undergoing Coronary Artery Bypass Surgery in Bushehr Heart Center: A Randomized Controlled Clinical Trial
Background: Coronary artery bypass graft surgery (CABG) with cardiopulmonary bypass pump may cause systemic inflammatory reactions by releasing cytokines which leads to multiple organ failure. Vitamin C has anti-inflammatory and antioxidant properties. The study aimed to determine the effect of vitamin C on inflammatory markers and atrial fibrillation in patients undergoing CABG. Materials and ...
متن کاملConservative Management of Dabigatran Overdose: Case Report and Review of Literature
Background: Direct thrombin inhibitors and factor Xa inhibitors are gaining popularity as alternatives to warfarin for patients requiring anticoagulation. Toxicity due to these medications is difficult to manage because overdose experience is very limited and there is no clear guidance on when or whether to use antidote in this setting. Case Presentation: A 50-year-old man with normal renal fu...
متن کاملEffect of Single-Dose Methotrexate Treatment on Ovarian Reserve in Women with Ectopic Pregnancy Undergoing Infertility Treatment: A Single-Center Experience
Background: The aim of this study was evaluation of the impact of single-dose methotrexate (MTX) treatment on ovarian reserve in women with ectopic pregnancy (EP) undergoing infertility treatment in Iranian population. Materials and Methods: This prospective cohort study was done between March 2015 and March 2017 in Tehran General Women Hospital, Tehran, Iran. We enrolled 20 patients with EP wh...
متن کاملOptimal Placement of Phasor Measurement Units in Khorasan Network Using a Hybrid Intelligent Technique
In this paper, an efficient and comprehensive hybrid intelligent technique for the optimal placement of phasor measurement units (PMUs) is proposed to minimize the number of PMU installation subjected to full network observability. Three main purposes of PMUs output synchronous measurements are monitoring, control, and protection of power system. We have combined Binary Imperialistic Competitio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of clinical and experimental medicine
دوره 8 4 شماره
صفحات -
تاریخ انتشار 2015