Comparison of Lesion Size Using Area and Volume in Full Field Digital Mammograms
نویسندگان
چکیده
The size of a lesion is a feature often used in computer-aided detection systems for classification between benign and malignant lesions. However, size of a lesion presented by its area might not be as reliable as volume of a lesion. Volume is more independent of the view (CC or MLO) since it represents three dimensional information, whereas area refers only to the projection of a lesion on a two dimensional plane. Furthermore, volume might be better than area for comparing lesion size in two consecutive exams and for evaluating temporal change to distinguish benign and malignant lesions. We have used volumetric breast density estimation in digital mammograms to obtain thickness of dense tissue in regions of interest in order to compute volume of lesions. The dataset consisted of 382 mammogram pairs in CC and MLO views and 120 mammogram pairs for temporal analysis. The obtained correlation coefficients between the lesion size in the CC and MLO views were 0.70 (0.64-0.76) and 0.83 (0.79-0.86) for area and volume, respectively. Twotailed z-test showed a significant difference between two correlation coefficients (p=0.0001). The usage of area and volume in temporal analysis of mammograms has been evaluated using ROC analysis. The obtained values of the area under the curve (AUC) were 0.73 and 0.75 for area and volume, respectively. Although a higher AUC value for volume was found, this difference was not significant (p=0.16).
منابع مشابه
Comparison of New and Established Full-Field Digital Mammography Systems in Diagnostic Performance
OBJECTIVE To compare the diagnostic performance of new and established full-field digital mammography (FFDM) systems. MATERIALS AND METHODS During a 15-month period, 1038 asymptomatic women who visited for mammography were prospectively included from two institutions. For women with routine two-view mammograms from established FFDM systems, bilateral mediolateral oblique (MLO) mammograms were...
متن کاملAdapting Breast Density Classification from Digitized to Full-Field Digital Mammograms
Mammographic density is strongly associated with breast cancer, being considered one of the most important risk indicators for the development of this type of disease. Likewise, the sensitivity of automatic breast lesion detection systems is significantly dependent on breast tissue characteristics. Therefore, the measurement of density is definitely useful for detecting breast cancer. The aim o...
متن کاملA dual-stage method for lesion segmentation on digital mammograms.
Mass lesion segmentation on mammograms is a challenging task since mass lesions are usually embedded and hidden in varying densities of parenchymal tissue structures. In this article, we present a method for automatic delineation of lesion boundaries on digital mammograms. This method utilizes a geometric active contour model that minimizes an energy function based on the homogeneities inside a...
متن کاملReducing Hardware Complexity of Wallace Multiplier Using High Order Compressors Based on CNTFET
Multiplier is one of the important components in many systems such as digital filters, digital processors and data encryption. Improving the speed and area of multipliers have impact on the performance of larger arithmetic circuits that are part of them. Wallace algorithm is one of the most famous architectures that uses a tree of half adders and full adders to increase the speed and red...
متن کاملMonte Carlo characterization of photoneutrons in the radiation therapy with high energy photons: a Comparison between simplified and full Monte Carlo models
Background: The characteristics of secondary neutrons in a high energy radiation therapy room were studied using the MCNPX Monte Carlo (MC) code. Materials and Methods: Two MC models including a model with full description of head components and a simplified model used in previous studies were implemented for MC simulations. Results: Results showed 4-53% difference between full and wit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012