A Novel Shunt Active Filter Algorithms for a Three Phase System with Unbalanced and Distorted Source Voltage Wave Forms Feeding to Adjustable Speed Drive

نویسنده

  • K. Sravanthi
چکیده

This paper presents the simulation of Shunt Active Power filter by using two different control schemes, indirect current control technique and ANN control technique. These two controle techniques are working under both balanced and unbalanced three phase voltage source conditions and it is feeding to a adjustable speed drive the torque speed characteristics of a motor is presented. Indirect current control technique is implemented under dynamic load condition and load balanced condition. ANN control technique theory is used here to calculate the three phase line currents and voltages, the average power is determined and distributed proportionally among the three phases according to their instantaneous phase voltage. From this power we are calculating the compensating currents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method

This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...

متن کامل

A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...

متن کامل

Using the Schunt Active Power Filter for Compensation of the Distorted and Umbalanced Power System Voltage

In this paper, we apply the PQ theory with shunt active power filter in an unbalanced and distorted power system voltage to compensate the perturbations generated by non linear load. The power factor is also improved in the current source. The PLL system is used to extract the fundamental component of the even sequence under conditions mentioned of the power system voltage. Keywords—Converter, ...

متن کامل

Control strategies for harmonic mitigation and power factor correction using shunt active filter under various source voltage conditions

This paper gives a new insight into the concept of load compensation using shunt active filter (SAF) under ideal and non-ideal source voltage conditions. A novel approach based on an improved instantaneous active and reactive current component method is proposed. The performance of the proposed control strategy has been compared with instantaneous reactive power theory, symmetrical component th...

متن کامل

Real-Time Control of Shunt Active Power Filter under Distorted Grid Voltage and Unbalanced Load Condition Using Self Tuning Filter

In this study, an alternative control method is proposed to improve the harmonic suppression efficiency of the active power filter in a distorted and unbalanced power system to compensate the perturbations caused by unbalanced non-linear loads. The proposed method uses a selftuning filter (STF) to process the grid voltage in order to provide a uniform reference voltage to obtain the correct ang...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011