Clinical assessment of auto-positive end-expiratory pressure by diaphragmatic electrical activity during pressure support and neurally adjusted ventilatory assist.

نویسندگان

  • Giacomo Bellani
  • Andrea Coppadoro
  • Nicolò Patroniti
  • Marta Turella
  • Stefano Arrigoni Marocco
  • Giacomo Grasselli
  • Tommaso Mauri
  • Antonio Pesenti
چکیده

BACKGROUND Auto-positive end-expiratory pressure (auto-PEEP) may substantially increase the inspiratory effort during assisted mechanical ventilation. Purpose of this study was to assess whether the electrical activity of the diaphragm (EAdi) signal can be reliably used to estimate auto-PEEP in patients undergoing pressure support ventilation and neurally adjusted ventilatory assist (NAVA) and whether NAVA was beneficial in comparison with pressure support ventilation in patients affected by auto-PEEP. METHODS In 10 patients with a clinical suspicion of auto-PEEP, the authors simultaneously recorded EAdi, airway, esophageal pressure, and flow during pressure support and NAVA, whereas external PEEP was increased from 2 to 14 cm H2O. Tracings were analyzed to measure apparent "dynamic" auto-PEEP (decrease in esophageal pressure to generate inspiratory flow), auto-EAdi (EAdi value at the onset of inspiratory flow), and IDEAdi (inspiratory delay between the onset of EAdi and the inspiratory flow). RESULTS The pressure necessary to overcome auto-PEEP, auto-EAdi, and IDEAdi was significantly lower in NAVA as compared with pressure support ventilation, decreased with increase in external PEEP, although the effect of external PEEP was less pronounced in NAVA. Both auto-EAdi and IDEAdi were tightly correlated with auto-PEEP (r = 0.94 and r = 0.75, respectively). In the presence of auto-PEEP at lower external PEEP levels, NAVA was characterized by a characteristic shape of the airway pressure. CONCLUSIONS In patients with auto-PEEP, NAVA, compared with pressure support ventilation, led to a decrease in the pressure necessary to overcome auto-PEEP, which could be reliably monitored by the electrical activity of the diaphragm before inspiratory flow onset (auto-EAdi).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diaphragmatic electrical activity: a new tool to assess lung hyperinflation?

447 September 2014 “ EXPIRATION and slow decrease of light together reaching minimum together ... in about 10 s and immediately cry as before. Silence and hold for about 5 s.” In the script for his late play “Breath,” Samuel Beckett conveys in sound and light his awareness of long and vital expiratory times. His personal experience with emphysema might have provided some of the inspiration. In ...

متن کامل

Impact of prolonged assisted ventilation on diaphragmatic efficiency: NAVA versus PSV

BACKGROUND Prolonged controlled mechanical ventilation depresses diaphragmatic efficiency. Assisted modes of ventilation should improve it. We assessed the impact of pressure support ventilation versus neurally adjusted ventilator assist on diaphragmatic efficiency. METHOD Patients previously ventilated with controlled mechanical ventilation for 72 hours or more were randomized to be ventilat...

متن کامل

0438. Effects of positive end-expiratory pressure (PEEP) on the pattern of breathing during neurally adjusted ventilatory assist. A pilot study in a mild ards porcine model

Introduction Spontaneous breathing during mechanical ventilation is still controversial. It is well known that incongruous patterns of mechanical ventilation can trigger or exacerbate lung injury. NAVA is a mode of mechanical ventilation that delivers ventilatory assist in proportion to the Electrical activity of the Diaphragm (EDi), which mirrors the performance of the whole respiratory system...

متن کامل

Neurally Adjusted Ventilatory Assist vs Pressure Support Ventilation During Noninvasive Mechanical Ventilation

Neurally adjusted ventilatory assist (NAVA) is an original approach to noninvasive ventilation that can improve patient-ventilator interaction and may infl uence physiologic outcomes 1 3 because the electrical activity of the diaphragm, a pneumatically independent signal, is used to control the timing and level of assist provided, regardless of the interface used. In a recent issue of CHEST (Ja...

متن کامل

Neurally adjusted ventilatory assist vs pressure support ventilation during noninvasive mechanical ventilation: another physiologic evaluation to consider?

Neurally adjusted ventilatory assist (NAVA) is an original approach to noninvasive ventilation that can improve patient-ventilator interaction and may infl uence physiologic outcomes 1 3 because the electrical activity of the diaphragm, a pneumatically independent signal, is used to control the timing and level of assist provided, regardless of the interface used. In a recent issue of CHEST (Ja...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 121 3  شماره 

صفحات  -

تاریخ انتشار 2014