A comparison of a left-sided Broncho-Cath with the torque control blocker univent and the wire-guided blocker.
نویسندگان
چکیده
UNLABELLED Lung isolation can be accomplished in two ways: the first, a double-lumen endotracheal tube (DLT) and the second, a bronchial blocker (Univent or Arndt blocker). Previous studies have found that the DLT and the Univent are comparable when providing lung isolation. A new bronchial blocker, the wire-guided endobronchial blocker (Arndt blocker), has been introduced. However, there is no study to report its effectiveness with lung isolation during elective thoracic surgical cases. Therefore, we designed a prospective, randomized trial to compare the effectiveness of lung isolation among the 3 endotracheal tubes: the left-sided DLT Broncho-Cath Group A (n = 16 patients), the torque control blocker Univent Group B (n = 16 patients), and the wire-guided Arndt blocker Group C (n = 32 patients). The following variables were recorded: 1) time to initially position the assigned tube, 2) frequency of malpositions, 3) frequency of use of fiberoptic bronchoscope, 4) overall surgical exposure, and 5) tube acquisition cost. The Arndt blocker took longer to place (3:34 min/s) compared with the other 2 groups: the DLT group (2:08 min/s) or the Univent group (2:38 min/s) (P < 0.0004). There was no statistical difference in tube malpositions among the three groups: two for the DLT group, four for the Univent group, and nine in the Arndt group. Excluding the time for tube placement, the Arndt group also took longer for the lung to collapse (26:02 min/s), compared with the DLT group (17:54 min/s) or Univent group (19:28 min/s) (P < 0.0060). Furthermore, unlike the other two groups, the majority of the Arndt patients required suction to achieve lung collapse. Once lung isolation was achieved, overall surgical exposure was rated excellent for the three groups. Acquisition cost for the DLT group was $1663.20 (21 tubes opened), $2329.00 for the Univent group (17 tubes opened), and $3567.00 for the Arndt group (33 wire-guided blockers opened). This study demonstrates that the Arndt blocker takes longer to position and longer to deflate the isolated lung. For elective thoracic surgical cases, once the lung was isolated, the management seemed to be similar for all three tube groups. IMPLICATIONS We compared the latest design of double-lumen tubes Broncho-Cath, Univent, and Arndt blockers during lung isolation. Our results show that the Arndt blocker takes longer to position and longer to deflate the isolated lung. Once the lung was isolated, the management seemed to be similar for all three devices.
منابع مشابه
An update on bronchial blockers during lung separation techniques in adults.
Techniques for one-lung ventilation (OLV) can be accomplished in two ways: The first involves the use of a double-lumen endotracheal tube (DLT). The second involves blockade of a mainstem bronchus (bronchial blockers). Bronchial blockade technology is on the rise, and in some specific clinical situations (e.g., management of the difficult airway during OLV or selective lobar blockade) it can of...
متن کاملBlind endobronchial insertion of a movable bronchial blocker attached to an endotracheal tube, Univent tube.
The endotracheal tube with a movable bronchial blocker, Univent tube, used to effect one-lung ventilation is easy to use in endotracheal intubation. However, problems are often encountered when inserting the blocker into the bronchus. We herein describe a method which enables the easy blind insertion of the blocker into the left or right bronchus. The techniques of inserting the blocker into th...
متن کاملRESPIRATION AND THE AIRWAY Randomized clinical trial comparing double-lumen tube and EZ-Blocker for single-lung ventilation
Editor’s key points † A new EZ bronchial blocker was compared with double-lumen tube (DLT) for providing single-lung ventilation (SLV). † Forty patients undergoing thoracic surgery were randomized to one of the two groups. † EZ-Blocker (EZ) provided comparable quality of lung collapse to DLT, but took longer for its placement. † EZ will be an efficient alternative for SLV where DLT cannot be us...
متن کاملComparison of a modified double-lumen endotracheal tube with a single-lumen tube with enclosed bronchial blocker.
This study compared the modified BronchoCath double-lumen endotracheal tube with the Univent bronchial blocker to determine whether there were objective advantages of one over the other during anesthesia with one-lung ventilation (OLV). Forty patients having either thoracic or esophageal procedures were randomly assigned to one of two groups. Twenty patients received a left-side modified Bronch...
متن کاملP-4: Zaditen (Ketotifen), as Mast Cell Blocker, Improves Sperm Quality, Chromatin Integrity and Pregnancy Rate after Varicocelectomy
Background: Surgery is considered the most common choice for the treatment of male infertility with clinical varicocele. Increased numbers of mast cells (MCs) have been associated with different types of infertility, including varicocele. Despite there being different reports on improved fertility following administration of MC blockers, there is no report on the effect of a MC blocker on varic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesia and analgesia
دوره 96 1 شماره
صفحات -
تاریخ انتشار 2003