Optimization and Calibration of a Low-background Liquid Scintillation Counter for the Simultaneous Determination of Alpha
نویسندگان
چکیده
The use of low-background liquid scintillation counting (ISC) techniques permits the simultaneous measurement of both alpha and beta emitters with efficiencies close to 100%. In this study, the counting parameters of a Wallac 1220TM Quantulus IS counter have been optimized for the best possible separation of the a and 3 spectra when measuring a sample containing 8 ml of water and 12 ml of Optiphase HiSafeTM 3 scintillation cocktail. For a normal quenching, minimum interference was observed when using an optimized a/3 pulse-shape discrimination value, PSA = 117 (which ranges from 1 to 256). As the detection limits were increased when using a pulse-amplitude comparator to reduce the background, this circuit was not activated during the experiment. In these conditions, the total interference between the a and 3 spectrum was -8%. This interference occurred only between the a window and the high-energy 3 window, and was little influenced by small variations of quenching. Better separation was achieved when the samples showed lower quenching. The figures of merit for the a and high-energy 3 windows were 144,000 and 1452 cpm-1, respectively, corresponding to efficiencies of 95% and 77%. The minimum detectable activities for a and high-energy f3 emitters in water samples were -0.15 Bq liter 1 and 1.36 Bq liter 1 for a total counting time of 360 min.
منابع مشابه
Determination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]
Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...
متن کاملDetermination of Amphetamine and Methamphetamine by Dispersive Liquid Phase Micro-extraction: A Novel Experimental Approach
Background: A syringe to syringe dispersive liquid phase micro-extraction-floating organic drop was applied and used for the simultaneous extraction and pre-concentration of trace amounts of amphetamine (AMP) and methamphetamine (MAMP) in urine samples. The extracted analytes were determined by high performance liquid chromatography along with diode array detection. Materials & Methods: In thi...
متن کاملSimultaneous determination of gross alpha, gross beta and ²²⁶Ra in natural water by liquid scintillation counting.
The determination of gross alpha, gross beta and (226)Ra activity in natural waters is useful in a wide range of environmental studies. Furthermore, gross alpha and gross beta parameters are included in international legislation on the quality of drinking water [Council Directive 98/83/EC]. In this work, a low-background liquid scintillation counter (Wallac, Quantulus 1220) was used to simultan...
متن کاملOptimization Method to Determine Gross Alpha-Beta in Water Samples Using Liquid Scintillation Counter
Liquid scintillation counting (LSC) is an adequate nuclear technique to determine radioactivity levels, as verified by this study for the determination of the gross alpha and beta activities of aqueous samples because of its simplicity and low associated cost comparison with other techniques. This paper discusses a new approach to the monitoring of gross alpha and gross beta activities in water...
متن کاملSimultaneous Determination of Sulfamethoxazole and Phthalazine by HPLC and Multivariate Calibration Methods
Two multivariate calibration methods are compared for the simultaneous chromatographic determination and separation of Sulfamethoxazole (SMX) and Phthalazine (PHZ) by High Performance Liquid Chromatography (HPLC). Multivariate calibration techniques such as Classical Least Squares (CLS) and Inverse Least Squares (ILS) were introduced into HPLC to determine the quantification by using UV d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006