Spontaneous variability and reactive postural beat-to-beat changes of integral ECG body surface potential maps.

نویسندگان

  • E Kellerová
  • V Szathmáry
  • G Kozmann
  • K Haraszti
  • Z Tarjányi
چکیده

There is virtually no information on spontaneous variability of ECG body surface potential maps (BSPMs) and on dynamics of their reactive changes in healthy subjects. This study evaluated quantitatively the depolarization (QRS) and repolarization (QRST) parameters derived from the respective integral BSPMs, constructed beat-to-beat, from continual body surface ECG records in 9 healthy men resting supine, during head-up tilting and sitting. Spontaneous variability of the BSPMs parameters, both at rest and during postural reactions, was characterized by significant respiratory and low frequency oscillations, more pronounced when related to repolarization. Head-up tilting and sitting-up evoked significant decrease in the QRST-BSPM amplitudes, widening of the angle alpha and reduction of nondipolarity indexes, compared to the respective supine values. All these changes were gradual, characterized by transition phenomena and prolonged after-effects. Tilting back to horizontal restored the resting supine values. The postural effects on depolarization were individually more variable and in the average showed a minimal QRS-BSPM amplitude increase. Beat-to-beat analysis of a train of ECG BSPMs provided the first evidence of spontaneous, non-random, respiratory and low frequency oscillations of the ventricular repolarization pattern, and the first insight into the dynamics of body posture associated changes in ventricular recovery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Importance of body surface potential field representation fidelity: analysis of beat-to-beat repolarization measurements.

OBJECTIVE According to previous studies, the complex substrate of malignant arrhythmias needs a detailed spatio-temporal noninvasive characterization of low-amplitude dynamic changes in beat-to-beat cardiac repolarization. METHODS Body surface potential map (BSPM) records were taken on 14 healthy male and female subjects (age 20-80 years) and on 6 ventricular arrhythmia patients, 4 of them wi...

متن کامل

Dynamic Beat-to-Beat Changes of the Cardiac Electric Field in Response to Situations with Increased Sympathetic Activity

Only a few studies – evaluating body surface potential maps (BSPMs) from a selected single beat, or from an average constructed of some heart beats have dealt with reactive changes of BSPMs in response to different physiological conditions. Our aim was to analyse the previously unexplored dynamic beat-to-beat pattern of the reactive changes in the ventricular depolarization and repolarization, ...

متن کامل

Effect of posture and isoproterenol on beat-to-beat heart rate and QT variability.

RATIONALE Recent literature emphasizes the utility of QT variability to study ventricular electrophysiologic function. In this investigation, we sought to test the hypothesis that beat-to-beat fluctuations in QT intervals are mediated by sympathetic activity in normal subjects using postural challenge and isoproterenol infusions. SUBJECTS AND METHODS We obtained ECG in the supine and standing...

متن کامل

Dependence of temporal variability of ventricular recovery on myocardial fibrosis. Role of mechanoelectric feedback?

OBJECTIVE The study was aimed at establishing the effect of factors involved in the expression of mechanoelectric feedback in the heart, such as R-R interval and connective tissue, on time dependent changes in ventricular recovery, as determined at the body surface by beat to beat variability of QRST integral maps (BBV-IM). METHODS We used 15 normal 6-month-old Wistar rats. In each anesthetiz...

متن کامل

Conventional QT Variability Measurement vs. Template Matching Techniques: Comparison of Performance Using Simulated and Real ECG

Increased beat-to-beat variability in the QT interval (QTV) of ECG has been associated with increased risk for sudden cardiac death, but its measurement is technically challenging and currently not standardized. The aim of this study was to investigate the performance of commonly used beat-to-beat QT interval measurement algorithms. Three different methods (conventional, template stretching and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological research

دوره 59 6  شماره 

صفحات  -

تاریخ انتشار 2010