Effects of temperature variation on MOSFET dosimetry.

نویسندگان

  • Tsang Cheung
  • Martin J Butson
  • Peter K N Yu
چکیده

This note investigates temperature effects on dosimetry using a metal oxide semiconductor field effect transistor (MOSFET) for radiotherapy x-ray treatment. This was performed by analysing the dose response and threshold voltage outputs for MOSFET dosimeters as a function of ambient temperature. Results have shown that the clinical semiconductor dosimetry system (CSDS) MOSFET provides stable dose measurements with temperatures varying from 15 degrees C up to 40 degrees C. Thus standard irradiations performed at room temperature can be directly compared to in vivo dose assessments performed at near body temperature without a temperature correction function. The MOSFET dosimeter threshold voltage varies with temperature and this level is dependent on the dose history of the MOSFET dosimeter. However, the variation can be accounted for in the measurement method. For accurate dosimetry, the detector should be placed for approximately 60 s on a patient to allow thermal equilibrium before measurements are taken with the final reading performed whilst still attached to the patient or conversely left for approximately 120 s after removal from the patient if initial readout was measured at room temperature to allow temperature equilibrium to be established.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation therapy treatment unit dose-rate effects on metal–oxide–semiconductor field-effect transistor (MOSFET) detectors

Metal oxide semiconductor field effect transistor (MOSFET) detectors have recently been introduced to radiation therapy. However, the response of these detectors is known to vary with dose rate. Therefore, it is important to evaluate how much variation between the treatment prescribed dose and the dose that is actually delivered to the patient using high-energy photon or electron beams under co...

متن کامل

Temperature Dependency of MOSFET Device Characteristics in 4H- and 6H-Silicon Carbide (SiC)

An analytical model for lateral MOSFET that includes the effects of temperature variation in 4Hand 6H-SiC poly-type is presented in this paper. SiC shows a tremendous potential for high temperature electronics applications [1-4]. The model includes the effects of temperature variation on the threshold voltage, the carrier mobility, the body leakage current, and the drain and source contact regi...

متن کامل

Effects of temperature variation (300–600 K) in MOSFET modeling in 6H–silicon carbide

Silicon carbide (SiC) based devices perform very well in severe environments and show excellent device characteristics at very high temperatures and in high radiation environments. An analytical model for a lateral MOSFET that includes the effects of temperature variation in 6H–SiC poly-type has been developed. The effects of elevated ambient and substrate temperatures (300–600 K) on the electr...

متن کامل

Analysis of Voltage Variation in Silicon Carbide MOSFETs during Turn-On and Turn-Off

Due to our limited knowledge about silicon carbide metal–oxide–semiconductor fieldeffect transistors (SiC MOSFETs), the theoretical analysis and change regularity in terms of the effects of temperature on their switching characteristics have not been fully characterized and understood. An analysis of variation in voltage (dVDS/dt) for SiC MOSFET during turn-on and turn-off has been performed th...

متن کامل

Rectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector

Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 49 13  شماره 

صفحات  -

تاریخ انتشار 2004