Comparison of volume controlled ventilation and pressure controlled ventilation in patients undergoing robot-assisted pelvic surgeries: An open-label trial
نویسندگان
چکیده
BACKGROUND AND AIMS Although volume controlled ventilation (VCV) has been the traditional mode of ventilation in robotic surgery, recently pressure controlled ventilation (PCV) has been used more frequently. However, evidence on whether PCV is superior to VCV is still lacking. We intended to compare the effects of VCV and PCV on respiratory mechanics and haemodynamic in patients undergoing robotic surgeries in steep Trendelenburg position. METHODS This prospective, randomized trial was conducted on sixty patients between 20 and 70 years belonging to the American Society of Anesthesiologist Physical Status I-II. Patients were randomly assigned to VCV group (n = 30), where VCV mode was maintained through anaesthesia, or the PCV group (n = 30), where ventilation mode was changed to PCV after the establishment of 40° Trendelenburg position and pneumoperitoneum. Respiratory (peak and mean airway pressure [APpeak, APmean], dynamic lung compliance [Cdyn] and arterial blood gas analysis) and haemodynamics variables (heart rate, mean blood pressure [MBP] central venous pressure) were measured at baseline (T1), post-Trendelenburg position at 60 min (T2), 120 min (T3) and after resuming supine position (T4). RESULTS Demographic profile, haemodynamic variables, oxygen saturation and minute ventilation (MV) were comparable between two groups. Despite similar values of APmean, APpeak was significantly higher in VCV group at T2 and T3 as compared to PCV group (P < 0.001). Cdyn and PaCO2 were also better in PCV group than in VCV group (P < 0.001 and 0.045, respectively). CONCLUSION PCV should be preferred in robotic pelvic surgeries as it offers lower airway pressures, greater Cdyn and a better-preserved ventilation-perfusion matching for the same levels of MV.
منابع مشابه
Benefits of lung-protective ventilation: looking beyond the ICU
Methods Objective: The aim of the study was to determine whether lung-protective ventilation improves outcomes in anesthetized patients undergoing major abdominal surgery. Design: The Intraoperative Protective Ventilation (IMPROVE) trial is a multicenter, open-label double-blind, parallel-group randomized control trial in seven French university hospitals. Setting: The IMPROVE study enrolled 40...
متن کاملComparison of the effect of pressure support ventilation and volume assured pressure support ventilation on weaning patients off mechanical ventilation after cardiac surgery
Background: Weaning from mechanical ventilation in the intensive care unit is an important step in the treatment process. More patients in less than 6 hours after cardiac surgery can be separated from mechanical ventilation and extubated. However, 20-40% of patients after cardiac surgery, due to dysfunctional ventilator weaning response (DVWR), still remain under mechanical ventilation. Therefo...
متن کاملVolume-guaranteed Ventilation Versus Pressure-controlled Ventilation in Preterm Infants with Respiratory Distress Syndrome: A Randomized Controlled Trial
Background: This study was targeted toward comparing volume-guaranteed (VG) ventilation with conventional pressure-controlled (PC) ventilation in preterm infants with respiratory distress syndrome (RDS) in terms of the facilitation of weaning and extubation and occurrence of complications, such as pneumothorax, intraventricular hemorrhage (IVH), retinopathy of prematur...
متن کاملComparison of the Effects of Open and Closed Endotracheal Suction on Cardiovascular and Ventilation Parameters for Patients Undergoing Mechanical Ventilation
Background and Objectives: Suction is a necessary and common method which aids in the release of secretion from the respiratory system for the patients who have undergone mechanical ventilation. One of the most common complications of suction is hypoxemia which causes dysrhythmia and death. The purpose of this study was to determine the effects of open and closed-endotracheal suction on cardiov...
متن کاملEarly Nasal Intermittent Positive Pressure Ventilation (NIPPV) versus Nasal Continuous Positive Airway Pressure (NCPAP) for Respiratory Distress Syndrome (RDS) in Infants of 28-36 weeks gestational age: a Randomized Controlled Trial
Background: Early nasal continuous positive airway pressure (NCPAP) has emerged as a primary modality of respiratory support for preterm infants withrespiratory distress syndrome (RDS). However, 30%-40% of these newborns need subsequent mechanical ventilation. Nasal intermittent positive pressure ventilation (NIPPV) is a promising alternative to NCPAP, especially in po...