Modeling, Control and Simulation of a Chain Link STATCOM in EMTP-RV
نویسندگان
چکیده
-This paper describes an alternative STATic synchronous COMpensator (STATCOM), by connecting a number of Gate Turn Off (GTO) thyristor converters in series on the ac side of the system. Each GTO converter forms one ‘link’ of a 1-phase, full-bridge Voltage-Source-Converter (VSC) and is referred to as a ‘Chain Link Converter’ (CLC). Each GTO of a CLS, is switched ‘ON/OFF’ only once per cycle of the fundamental frequency by using a Sinusoidal Pulse Width Modulation (SPWM) technique. Approximate models of a 3phase Chain Link STATCOM (CLS) using dq-transformation are used to design two controllers for controlling reactive current and ac voltage to stabilize the system voltage at the Point of Common Coupling (PCC). A novel technique, called the Rotated Gate Signal Pattern (RGSP), is used for balancing the voltages of the link dc capacitors. The performance investigation of the CLS system when used in a radial line is carried out under steadyand transient-state operating conditions by means of the simulation package; EMTP-RV and the results are presented.
منابع مشابه
Improving the Voltage Profile of the Power System Using PV-STATCOM
This paper presents a novel concept of utilizing the photo voltaic solar farm inverter as STATCOM(Static Compensator), named PV-STATCOM, in order to improve the voltage profile of the power system. The entire STATCOM is able to transmit either active or reactive power into the grid. This system is connected to a 14 BUS IEEE standard grid as a case study to simulate the performance of the system...
متن کاملBack-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems
The article presents the transients analysis of the substation grounding systems and transmission line tower footing resistances which can affect to the back-flashover (BF) or overvoltage across insulator chain in an HV power systems by using EMTP-RV software. The related transient modeling of the grounding systems is based on a transmission line (TL) model with considering the soil ionization....
متن کاملAnalysis of effective factors on transient ground potential rise in gas insulated substations
This study presents the manner in which transient modeling concepts, which are fully analyzed in the referred standards, are implemented, for the purpose of evaluating the Transient Ground Potential Rise (TGPR). This is a phenomenon of 10–100kV voltages with up to 10μs duration on the grounded enclosure of Gas Insulated Substations (GIS), which may cause concern for personnel safety and problem...
متن کاملAnalysis of effective factors on transient ground potential rise in gas insulated substations
This study presents the manner in which transient modeling concepts, which are fully analyzed in the referred standards, are implemented, for the purpose of evaluating the Transient Ground Potential Rise (TGPR). This is a phenomenon of 10–100kV voltages with up to 10µs duration on the grounded enclosure of Gas Insulated Substations (GIS), which may cause concern for personnel safety and pro...
متن کاملSTATCOM Modeling for Voltage and Angle Stability Studies
This paper proposes and validates models to accurately represent STATic Synchronous Shunt COMpensators (STATCOM) in voltage and angle stability studies of powers systems. The proposed STATCOM stability models are justified based on the basic operational characteristics of this Flexible AC Transmission System (FACTS) controller for both phase and PWM control strategies. These models are first va...
متن کامل