Analysis of benzyldimethyldodecylammonium bromide in chemical disinfectants by liquid chromatography and capillary electrophoresis.
نویسندگان
چکیده
Two novel analytical methodologies using capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC) were developed and compared for the determination of benzyldimethyldodecylammonium bromide (BAB) in commercial compound chemical disinfectants. The LC analysis was performed with a Kromasil C18 (200 mm x 4.6 mm, 5 microm) column and a mobile phase of A:B = 80:20 (A: acetonitrile, B: 4 mmol/L octanesulfonic sodium--0.02 mol/L acetic sodium, adjusted with acetic acid to pH 5.2) at a flow rate of 1.0 mL/min. Detection was by ultraviolet absorption at 262 nm. The CE analysis was performed in a bare fused-silica capillary with 75 microm i.d. and total length of 46.4 cm with a buffer solution of 50% acetonitrile -50 mmol/L NaH2PO4, pH 2.24. The applied voltage was 20 kV. Detection was by ultraviolet absorption at 214 nm. Under optimized conditions, the HPLC retention time and CE migration time for BAB was 9.18 and 5.08 min, respectively. Calibration curves of peak area versus concentration gave correlation coefficients of 0.9996 for HPLC and 0.9994 for CE. The detection limits for HPLC and CE were 1.6 mg/L and 0.2 mg/L, respectively. Average recoveries at three concentration levels (50, 100, 200 mg/L for HPLC: 20, 40, 100 mg/L for CE) were 99.94 +/- 1.5, 99.64 +/- 1.3 and 99.61 +/- 0.4% for HPLC and 120.47 +/- 2.6, 102.06 +/- 8.7 and 103.05 +/- 3.0% for CE, respectively. Although both methods were shown to be suitable for the determination of BAB in commercial disinfectant compounds, CE provided analysis with less solvent purchase/disposal and better column efficiency, whereas HPLC provided superior precision.
منابع مشابه
[Simultaneous determination of chlorhexidine acetate and benzalkonium chloride in compound chemical disinfectants by capillary electrophoresis].
Benzalkonium chloride (BAC) is a mixture of alkyl substituted benzyl dimethylammonium chloride homologs (C12-BAC, C14-BAC and C16-BAC). Chlorhexidine acetate is a widely used effective component in compound chemical disinfectants. A method for the simultaneous determination of chlorhexidine acetate and benzalkonium chloride in compound chemical disinfectants by capillary electrophoresis (CE) wa...
متن کاملChemical modification of analytes in speciation analysis by capillary electrophoresis, liquid chromatography and gas chromatography.
Chemical modification of target analytes is widely used in modern analytical methods. This review focuses on the application of chemical modification techniques is the simultaneous analysis of metallic species by capillary electrophoresis, liquid chromatography and gas chromatography. Emphasis is placed on the procedures relating to analyses carried out by capillary electrophoresis. The develop...
متن کاملSimultaneous determination of heavy metals in drinking waters and wines by methods: Ion pair-reversed phase high performance liquid chromatography and capillary zone electrophoresis
Simultaneous determination of metal ions in drinking waters and wines using ion paired reversed phase high performance liquid chromatography (IP−RPHPLC) and capillary zone electrophoresis (CZE) have been investigated. Co(II), Cu(II), Ni(II), Fe(II) and V(V) are analyzed as their Nitro-PAPS chelates. Reversed flow injection (rFI) is used for in-line complexation prior to their separation by IP-R...
متن کاملStudy of posttranslational non-enzymatic modifications of collagen using capillary electrophoresis/mass spectrometry and high performance liquid chromatography/mass spectrometry.
The depository effects that occur in slowly metabolized proteins (typically glycation) are very difficult to assess, owing to their extremely low concentration in the protein matrix. Collagen accumulates reactive metabolites through reactions that are not regulated by enzymes. A typical example of these non-enzymatic changes is glycation (the Maillard reaction, the formation of advanced glycati...
متن کاملCapillary zone electrophoresis of collagen type I CNBr peptides in acid buffers.
Collagen type-I CNBr peptides were separated under acidic conditions by capillary electrophoresis. Separation conditions were: 100 mM phosphate buffer pH 2.5, 50 cm x 50 microns capillary (placed in a cartridge), 8 kV, running time 30-45 min, detection by UV at 200 nm. The peptides were separated strictly by their molecular mass and the overall pattern was well comparable to RP-HPLC separations...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 1039 1-2 شماره
صفحات -
تاریخ انتشار 2004