Enzymic assay of plasma cholesterol: a comparison of analytical variations found using the Greiner GSA II and the Technicon SMA 12/60 and SMA II.

نویسندگان

  • J Steinmetz
  • E Panek
  • E Gaspart
چکیده

Cholesterol was assayed on the Greiner GSA II and the Technicon SMA 12/60 and SMA II autoanalyzers, with Allain's entirely enzymic method (Allain et al. (1974), Clin. Chem. 20, 470--475). The coefficients of variation in the results over a period of one month were less than 6% with the GSA II and the SMA II, but up to 9% on the SMA 12/60. Although the accuracy of the enzymic method depends on the specificity of the cholesterol oxidase and cholesterol esterase, the results were in good agreement with those obtained by Abell's method (Abell et al. (1952), J. Biol. Chem. 195, 357--366) on fresh or freeze dried human plasma. The cholesterol concentration was stable at 4 degrees C, or in frozen or freeze dried plasma. None of the drugs tested interfered with the enzymic assay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synthesized some copolymer derivative of poly (Styrene –alternative- Maleic Anhydride) (SMA) for removal Cobalt (II) ions from aqueous solutions and determination residual cobalt (II) ions by using spectrophotometric method

Chelating resins have been considered to be suitable materials for the recovery of heavy metals in water treatments. A chelating resin based on modified poly(styrene-alt-maleic anhydride) with Melamine was synthesized. This modified resin was further reacted with 1,2-diaminoethan in the presence of ultrasonic irradiation for the preparation of a tridimensional chelating resin on the nanoscale f...

متن کامل

Comparison of plasma creatinine determined with the Greiner Selective Analyser GSA II and the glomerular filtration rate.

1. Reference values for the plasma creatinine were established using the alkaline picrate method with the Greiner Selective Analyzer GSA II in relation to the Cr 51-EDTA Clearance. Individuals with normal GFR between 93 to 159 ml/min/1.73 m2 had creatinine values in men (n = 65) from 53.7 to 119.5 mumol/l (0.61 to 1.35 mg/100 ml) and in women (n = 59) from 37.7 to 107 mumol/l (0.42 to 121 mg/10...

متن کامل

Comparison of results from the Du Pont "ACA" and Technicon "SMA 12-60".

The Du Pont “Automatic Clinical Analyzer” (ACA) and the Technicon “SMA 12/60” were compared as to precision, range of linearity, and results for sera from patients. Precision of the ACA was equal to or better than that of the SMA 12/60 for all determinations except SGOT in the normal range. The ACA showed a wider range of linearity for BUN, total protein, LDH, alkaline phosphatase, SGOT, and bi...

متن کامل

بررسی میزان لیپوپروتئین – آ در پلاسمای مبتلایان به دیابت نوع II

Introduction: Lipoprotein (a) is a particle rich in cholesterol in human plasma and it is known as an independent risk factor for coronary artery disease. In addition to genetic background, other factors such as diabetes affect the plasma concentration of this lipoprotein as a risk factor. The aim of this study was evaluation and comparison of plasma concentration of Lp(a) in type II diabetics ...

متن کامل

Determination of serum calcium by use of an AutoAnalyzer I-II hybrid.

A hybridized system is described for the continuousflow determination of serum calcium. The analysis is based on the cresolphthalein colorimetric procedure as described for use with the SMA 12/60 (Technicon Corp.). The hydraulic features of the AutoAnalyzer II are used with modules of the AutoAnalyzer 1. This combination gives both the ease of operation and hydraulic improvements inherent in th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie

دوره 17 8  شماره 

صفحات  -

تاریخ انتشار 1979