About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study.
نویسندگان
چکیده
The accurate measurement of local strain is necessary to study bone mechanics and to validate micro computed tomography (µCT) based finite element (FE) models at the tissue scale. Digital volume correlation (DVC) has been used to provide a volumetric estimation of local strain in trabecular bone sample with a reasonable accuracy. However, nothing has been reported so far for µCT based analysis of cortical bone. The goal of this study was to evaluate accuracy and precision of a deformable registration method for prediction of local zero-strains in bovine cortical and trabecular bone samples. The accuracy and precision were analyzed by comparing scans virtually displaced, repeated scans without any repositioning of the sample in the scanner and repeated scans with repositioning of the samples. The analysis showed that both precision and accuracy errors decrease with increasing the size of the region analyzed, by following power laws. The main source of error was found to be the intrinsic noise of the images compared to the others investigated. The results, once extrapolated for larger regions of interest that are typically used in the literature, were in most cases better than the ones previously reported. For a nodal spacing equal to 50 voxels (498 µm), the accuracy and precision ranges were 425-692 µε and 202-394 µε, respectively. In conclusion, it was shown that the proposed method can be used to study the local deformation of cortical and trabecular bone loaded beyond yield, if a sufficiently high nodal spacing is used.
منابع مشابه
Numerical Study of the Effect of Materials’ Plastic Behavior on Equibiaxial Residual Stress Measurement Using Indentation
Indentation is a new method for estimating residual stress. The plastic behavior of the materials under study can affect indentation parameters and, thus, influences the results of residual stress measurement. In this paper, the effect of yield stress and work-hardening exponent on the accuracy of residual stress measurements in steels and aluminums was studied. Results showed that, for m...
متن کاملSimultaneous measurement of three-dimensional joint kinematics and ligament strains with optical methods.
The objective of this study was to assess the precision and accuracy of a nonproprietary, optical three-dimensional (3D) motion analysis system for the simultaneous measurement of soft tissue strains and joint kinematics. The system consisted of two high-resolution digital cameras and software for calculating the 3D coordinates of contrast markers. System precision was assessed by examining the...
متن کاملEffect of Abutment Angulation and Material on Stress and Strain Distributions in Premaxillary Bone: A Three-Dimensional Finite Element Analysis
Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA). Materials and Methods: Four three-dimensional (3D) fi...
متن کاملمقایسه اثر مواد مختلف سازنده ساختار فلزی روکش بر توزیع تنش پیرامون ایمپلنت با آنالیز اجزاء محدود سه بعدی
Objectives: Despite the high success rate, implant-supported prostheses fail in some cases. Control of the applied forces is an important factor determining the success or failure of implants. Complete understanding of the biomechanical principles in implant-supported prostheses is necessary for offering an appropriate custom-made treatment plan for each patient and reducing the risk of functio...
متن کاملComparison of the Efficacy of Digital Caliper and a Newly Designed Digital Bone Gauge for Measurement of Edentulous Alveolar Ridge Width
Objectives: An efficient, safe, affordable and easily accessible measuring instrument for quantitative assessment of bone prior to dental implant placement enables more accurate treatment planning. Costly imaging modalities are neither widely available, nor affordable for some patients. This study sought to assess the efficacy of a newly designed digital bone gauge for measurement of bone width...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 47 12 شماره
صفحات -
تاریخ انتشار 2014