Analysis of inflammatory cytokines in human blood, breath condensate, and urine using a multiplex immunoassay platform.
نویسندگان
چکیده
A change in the expression of cytokines in human biological media indicates an inflammatory response to external stressors and reflects an early step along the adverse outcome pathway (AOP) for various health endpoints. To characterize and interpret this inflammatory response, methodology was developed for measuring a suite of 10 different cytokines in human blood, exhaled breath condensate (EBC), and urine using an electrochemiluminescent multiplex Th1/Th2 cytokine immunoassay platform. Measurement distributions and correlations for eight interleukins (IL) (1β, 2, 4, 5, 8, 10, 12p70 and 13), interferon-γ (IFN-γ), and tumor necrosis factor-α (TNF-α) were evaluated using 90 blood plasma, 77 EBC, and 400 urine samples collected from nominally healthy adults subjects in North Carolina in 2008-2012. The in vivo results show that there is sufficient sensitivity for characterizing all 10 cytokines at levels of 0.05-0.10 ρg/ml with a dynamic range up to 100 ng/ml across all three of these biological media. The measured in vivo results also show that the duplicate analysis of blood, EBC and urine samples have average estimated fold ranges of 2.21, 3.49, and 2.50, respectively, which are similar to the mean estimated fold range (2.88) for the lowest concentration (0.610 ρg/ml) from a series of spiked control samples; the cytokine method can be used for all three biological media. Nine out of the 10 cytokines measured in EBC were highly correlated within one another with Spearman ρ coefficients ranging from 0.679 to 0.852, while the cytokines measured in blood had a mix of negative and positive correlations, ranging from -0.620 to 0.836. Almost all correlations between EBC and blood were positive. This work also represents the first successful within- and between-person evaluation of ultra trace-level inflammatory markers in blood, EBC, and urine.
منابع مشابه
Collection of Aerosolized Human Cytokines Using Teflon® Filters
BACKGROUND Collection of exhaled breath samples for the analysis of inflammatory biomarkers is an important area of research aimed at improving our ability to diagnose, treat and understand the mechanisms of chronic pulmonary disease. Current collection methods based on condensation of water vapor from exhaled breath yield biomarker levels at or near the detection limits of immunoassays contrib...
متن کاملMethadone concentrations in exhaled breath condensate, serum and urine of patients under maintenance treatment
Drug abuse is a serious problem causing health, economical and psycho-social negative outcomes. Methadone is commonly used drug for management of drug addiction. Exhaled breath condensate (EBC) is a promising non-invasive biological sample which attracted more attention in recent years. This work aimed to extend the applicability of a developed preconcentration – liquid chromatographic method f...
متن کاملMethadone concentrations in exhaled breath condensate, serum and urine of patients under maintenance treatment
Drug abuse is a serious problem causing health, economical and psycho-social negative outcomes. Methadone is commonly used drug for management of drug addiction. Exhaled breath condensate (EBC) is a promising non-invasive biological sample which attracted more attention in recent years. This work aimed to extend the applicability of a developed preconcentration – liquid chromatographic method f...
متن کاملسنجش نشانگر زیستی IL-6در هوای بازدمی با استفاده از دستگاه جمعآورنده میعانات بازدمی
Background and Objective: The collection of exhaled breath condensate (EBC) is a noninvasive, safe and simple technique to obtain direct samples from lung and use for estimation of the effects of air pollution on human subjects. EBC contains several compounds including simple ions, hydrogen peroxide, proteins, cytokines, deoxyribonucleic acid (DNA), creatine, Electrolytes, trace elements and to...
متن کاملMatrix effect in exhaled breath condensate interferon-gamma immunoassay.
Manuscripts presenting cytokine (and other protein) concentrations in exhaled breath condensate (EBC) are commonly published with insufficient control experiments performed to provide confidence that the assay was accurate. Our laboratory has identified false positives in EBC with several forms of immunoassay, including ELISA and multiplex bead arrays. In this current brief investigation, we st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomarkers : biochemical indicators of exposure, response, and susceptibility to chemicals
دوره 20 1 شماره
صفحات -
تاریخ انتشار 2015