High resolution magnetic resonance imaging of the anal sphincter using an internal coil.

نویسندگان

  • N M deSouza
  • W A Kmiot
  • R Puni
  • A S Hall
  • M Burl
  • C I Bartram
  • G M Bydder
چکیده

An internal receiver coil was used to obtain high resolution transverse and oblique coronal magnetic resonance images of the anal sphincter in five normal volunteers and five patients. The internal sphincter had a high signal intensity on T1 weighted, T2 weighted, and STIR sequences whereas the conjoined longitudinal muscle and external sphincter had a low signal intensity. The internal sphincter (but not the external sphincter) showed contrast enhancement after administration of intravenous gadopentetate dimeglumine. The oblique coronal plane was particularly useful for showing the thickness and the relations of the external sphincter. Sphincteric abscesses as well as muscle defects, hypertrophy, and atrophy were clearly shown. The coil was well tolerated by most subjects. It has considerable potential for improving the diagnosis of anorectal disease.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Static Coil Design Considerations for the Magnetic Resonance Imaging

One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...

متن کامل

3-D RF Coil Design Considerations for MRI

High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...

متن کامل

An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Gut

دوره 37 2  شماره 

صفحات  -

تاریخ انتشار 1995