Measurement of Hyperion MTF from On-Orbit Scenes

نویسندگان

  • N. R. Nelson
  • P. S. Barry
چکیده

The Hyperion instrument was launched November 21, 2000 mounted on the EO-1 spacecraft into orbit 1 minute behind Landsat 7. Hyperion has a 7.5 km swath width, a 30 meter ground resolution and more than 220 spectral bands. Part of the on-orbit characterization involves MTF measurements from several ground scenes. These scenes included edges from the moon and glaciers as well as several bridges. The scenes were processed to determine the MTF for both the VNIR and SWIR imaging spectrometers and were compared to measurements made prior to launch.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Chaotic Rotation of Hyperion

A plot of spin rate versus orientation when Hyperion is at the pericenter of its orbit (surface of section) reveals a large chaotic zone surrounding the synchronous spin-orbit state of Hyperion, if the satellite is assumed to be rotating about a principal axis which is normal to its orbit plane. This means that Hyperion's rotation in this zone exhibits large, essentially random variations on a ...

متن کامل

Modulation Transfer Function Measurement Method and Results for the Orbview-3 High Resolution Imaging Satellite

The Modulation Transfer Function (MTF) is a fundamental imaging system design specification and system quality metric often used in remote sensing. MTF is defined as the normalized magnitude of the Fourier Transform of the imaging system’s point spread function. Alternatively, the MTF describes the attenuation of sinusoidal waveforms as a function of spatial frequency. Practically, MTF is a met...

متن کامل

Compatibility Analysis of Multi-Sensor Vegetation Indices Using EO-1 Hyperion Data

In this study, we used a set of hyperspectral Hyperion scenes and assessed the effects of differing spectral and spatial resolutions on MODIS-AVHRR vegetation index (VI) continuity. Hyperion scenes were processed to simulate atmospherically-corrected normalized difference vegetation index (NDVI) and 2-band enhanced vegetation index (EVI2) values at MODIS Climate Modeling Grid (CMG) and AVHRR Gl...

متن کامل

Defocusing Effect Studies in MTF of CCD Cameras Based on PSF Measuring Technique

Defocusing effects in modulation transfer function (MTF) measurement of charge coupled device (CCD) cameras is the main focus of current paper. We introduce measuring Point-spread function (PSF) in order to calculate the MTF and further more we will study the shape of MTF and its cut-off frequency by adjusting the lens focusing in different locations. A collimated white light LED by broadband s...

متن کامل

محاسبۀ تابع انتقال مدولاسیون برای بررسی کنترل کیفی در رادیولوژی دیجیتال

The usage of digital radiology systems with insufficient quality control of digital image detectors can efface inherent superiorities of digital systems in comparison with analogue radiology systems and even makes an increased level of patients’ radiation doses. Modulation transfer function (MTF) is one of the most important parameters related to image quality and digital detectors efficiency. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001