Establishment of diagnostic reference levels for CT trunk examinations in the western region of Saudi Arabia.

نویسندگان

  • Abdulaziz A Qurashi
  • Louise A Rainford
  • Shane J Foley
چکیده

Diagnostic reference levels (DRLs) are an important optimisation tool, which aid in identifying abnormally high dose levels. These are currently not available in Saudi Arabia, and this research aims to remedy this. CT dose data (DLP and CTDIvol) were collected for a minimum number of 10 adult patients of average size (60-80 kg) presenting for a range of CT examinations from public hospitals in the western region of Saudi Arabia. These include routine chest, high-resolution chest (HRCT), pulmonary angiography (CTPA), abdomen and pelvis (AP) and the combined chest, abdomen and pelvis (CAP) CT examinations. Mean values for each site were calculated, and the 75th percentile of DLP and CTDIvol was used as a basis for DRLs. Data for 550 patients were collected from 14 hospitals over a 7-month period. The rounded third-quartile CTDIvol and DLP were 18 mGy and 630 mGy cm(-1) for chest CT, 20 mGy and 600mGy cm(-1) for HRCT, 18 mGy and 480 mGy cm(-1) for CTPA, 15 mGy and 800 mGy cm(-1) for AP, and 16 mGy and 1040 mGy cm(-1) for CAP, respectively. Regional DRLs have been proposed from this study. Dose variations across CT departments have identified an urgent need for optimisation to improve distribution of observed doses for CT examinations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Establishment of CT diagnostic reference levels in select procedures in South India

Background: To suggest South India CT diagnostic reference levels (DRLs) by collecting radiation doses for the most commonly performed CT examinations. Materials and Methods: A pilot study investigated the most frequent CT examinations. 110 CT sites were asked to complete a survey booklet to allow the recording of CT parameters for each of 3 CT examinations during a 1 year time period. Dose...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

Assessment of dose reduction and influence of gantry rotation time in CT abdomen examinations

Background: Worldwide the computed tomography (CT) scanning is recognized as a high radiation dose modality. This article aimed to estimate the radiation dose reduction and radiogenic risks for adult patients undertaking abdominal CT examinations. Materials and Methods: A total of 128 patients were studied using 2, 4, 16 and 64 slice CT scanners. The patients were divided into two categories: t...

متن کامل

Establishment of Diagnostic Reference Levels and Estimation of Effective Dose from Computed Tomography Head Scans at a Tertiary Hospital in South Africa

Introduction: Head scans are the most frequently performed computed tomography (CT) examinations worldwide. However, there is growing concern over the probability of increased cancer risks among the exposed populations. Diagnostic reference levels (DRLs) identify radiation dose that is not commensurate with clinical objectives. The aim of this study was to establish DR...

متن کامل

Diagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey

Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 167 4  شماره 

صفحات  -

تاریخ انتشار 2015