Comparison of relative quasi-molecular ion yields for 8-keV ion and 252Cf fission fragment bombardment.
نویسندگان
چکیده
related to the relatively small number of total ions utilized for determining the mass spectra. CONCLUSION It would be a significant advance if the mass resolution of 1500 obtained with inorganic specimens could be retained with nonvolatile and thermally labile organic specimens as well as obtaining the structurally significant fragment ion signals. This advance will require more detailed studies of substrate preparation, specimen deposition, faster lasers, and a variety of different samples. ACKNOWLEDGMENT We gratefully acknowledge C.
منابع مشابه
Comparison of Mass Spectra Obtained with Low-Energy Ion and High-Energy Californium-252 Fission Fragment Bom bardment
A direct comparlson Is made of the mass spectra of several involatile compounds obtained by using 252Cf ission fragment lonlratlon and iow-energy Ion bombardment using klloelectronvol! K+ and Cs’ ions. The comparisons were made on the same samples mounted on the same folk and mass determinations were made by using the time-of-flight principle. A very hlgh degree of slmllarity was observed In th...
متن کاملC60 molecular depth profiling of a model polymer
The bombardment of a 26 nm poly(methyl methacrylate) (PMMA) film has been studied as a model for depth profiling of polymeric samples using a newly developed C60 þ ion source. Experiments were conducted on a ToF-SIMS instrument equipped with C60 þand Gaþ ion sources. A focused dc C60 þ ion beam was used to etch through the polymer sample at specified time intervals. Subsequent spectra were reco...
متن کاملFAST ATOM BOMBARDMENT MASS SPECTROMETRY (FABMS) ANALYSIS OF AN N- TERMINAL - BLOCKED PEPTIDE
FABMS analysis of T-lb peptide before and after one cycle of Edman degradation indicated an unblocked N-terminal Thr residue for this tryptic peptide. In contrast , our data showed a molecular protonated ion, MH + for T- la peptide at 655 mass units (mu) which is 42 mu higher than the MH ion of T- 1b peptide. In addition, T- la peptide was not amenable to one cycle of manual Edman degrada...
متن کاملCarbon-13 labeled polymers: an alternative tracer for depth profiling of polymer films and multilayers using secondary ion mass spectrometry.
13C labeling is introduced as a tracer for depth profiling of polymer films and multilayers using secondary ion mass spectrometry (SIMS). Deuterium substitution has traditionally been used in depth profiling of polymers but can affect the phase behavior of the polymer constituents with reported changes in both bulk-phase behavior and surface and interfacial interactions. SIMS can provide contra...
متن کاملHigh Energy Sputtering from Cleaned Metal Foils *
Positive and negative secondary ions desorbed from metal foils by bombardment with 252Cf fission products have been investigated by time-of-flight mass spectroscopy. The measurements were performed under UHV conditions using metal foils of Cu, Ni and Al cleaned by Ar-ion etching. Spectra were taken with cleaned surfaces and also under the exposure of H2 , 0 2 , N2 , CO, C2H4 , C2H6 and C3H70H u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 60 15 شماره
صفحات -
تاریخ انتشار 1988