Randomized Controlled Trial of Radiation Protection With a Patient Lead Shield and a Novel, Nonlead Surgical Cap for Operators Performing Coronary Angiography or Intervention.

نویسندگان

  • Ashraf Alazzoni
  • Chris L Gordon
  • Jaffer Syed
  • Madhu K Natarajan
  • Michael Rokoss
  • Jon-David Schwalm
  • Shamir R Mehta
  • Tej Sheth
  • Nicholas Valettas
  • James Velianou
  • Shaheen Pandie
  • Darar Al Khdair
  • Michael Tsang
  • Brandi Meeks
  • Kiersten Colbran
  • Ed Waller
  • Shun Fu Lee
  • Tamara Marsden
  • Sanjit S Jolly
چکیده

BACKGROUND Interventional cardiologists receive one of the highest levels of annual occupational radiation exposure. Further measures to protect healthcare workers are needed. METHODS AND RESULTS We evaluated the efficacy of a pelvic lead shield and a novel surgical cap in reducing operators' radiation exposure. Patients undergoing coronary angiography or percutaneous coronary intervention (n=230) were randomized to have their procedure with or without a lead shield (Ultraray Medical, Oakville, Canada) placed over the patient. During all procedures, operators wore the No Brainer surgical cap (Worldwide Innovations and Technology, Kansas City, KS) designed to protect the head from radiation exposure. The coprimary outcomes for the lead shield comparison were (1) operator dose (µSv) and (2) operator dose indexed for air kerma (µSv/mGy). For the cap comparison, the primary outcome was the difference between total radiation dose (µSv; internal and external to cap). The lead shield use resulted in a 76% reduction in operator dose (mean dose, 3.07; 95% confidence interval [CI], 2.00-4.71 µSv lead shield group versus 12.57; 95% CI, 8.14-19.40 µSv control group; P<0.001). The mean dose indexed for air kerma was reduced by 72% (0.004; 95% CI, 0.003-0.005 µSv/mGy lead shield group versus 0.015; 95% CI, 0.012-0.019 µSv/mGy control group; P<0.001). The cap use resulted in a significant reduction in operator head radiation exposure (mean left temporal difference [external-internal] radiation dose was 4.79 [95% CI, 3.30-6.68] µSv; P<0.001). CONCLUSIONS The use of a pelvic lead shield and the cap reduced significantly the operator radiation exposure and can be easily incorporated into clinical practice. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT02128035.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Breast Radiation Protection in Coronary Angiography

Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...

متن کامل

Impact of Inhalation Aromatherapy with Damask Rose on Anxiety of Patients Undergoing Coronary Angiography: A Single-Blind Randomized Controlled Clinical Trial

Introduction: Coronary artery angiography is a common diagnostic procedure in cardiovascular diseases which could cause fear, stress, anxiety and probably some instability at hemodynamic parameters in the patients before this diagnostic procedure. This study aimed to assess impact of inhalation aromatherapy with damask rose on anxiety of patients undergoing coronary angiography. Methods: A sin...

متن کامل

Efficacy of the RADPAD Protection Drape in Reducing Operators' Radiation Exposure in the Catheterization Laboratory: A Sham-Controlled Randomized Trial.

BACKGROUND Interventional cardiologists are increasingly exposed to radiation-induced diseases like cataract and the stochastic risk of left-sided brain tumors. The RADPAD is a sterile, disposable, lead-free shield placed on the patient with the aim to minimize operator-received scatter radiation. The objective of the trial was to examine the RADPAD's efficacy in a real-world situation. METHO...

متن کامل

The effect of inhalation of peppermint aroma on anxiety in patients undergoing coronary angiography

Background & Aim: Anxiety is one of the most important mental problems in patients who are candidate for coronary angiography, which can have negative physiological and psychological consequences and ultimately lead to the increased hospital stay, increased patient need for analgesics, increased costs and increased incidence of angiographic complications. Therefore, the aim of this study was to...

متن کامل

Effect of Heparin Administration during Coronary Angiography on Vascular or Peripheral Complications: A Single-Blind Randomized Controlled Clinical Trial

Background: Coronary angiography consists of the selective injection of contrast agents in coronary arteries. Optimal strategy for heparin administration during coronary angiography has yet to be determined. We assessed the effect of heparin administration during coronary angiography on vascular, hemorrhagic, and ischemic complications.Methods: Five hundred candiates for diagnostic coronary ang...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 8 8  شماره 

صفحات  -

تاریخ انتشار 2015