Pass-band balanced SSFP fMRI at 7 Tesla
نویسندگان
چکیده
INTRODUCTION In fMRI, gradient-echo (GRE) single shot EPI allows a reasonable spatiotemporal resolution with robust functional activation. However, the combination of the long readout duration and echo time makes the method susceptible to image distortion, image blurring and signal dropout. Recently, balanced SSFP (bSSFP) fMRI has been proposed as an alternative method to compensate for these shortcomings [1-4]. In a previous study, feasibility of bSSFP fMRI was demonstrated at 7 T using small-flip-angle (4o and 7o transition-band SSFP fMRI [4]). A limitation of this study was the limited spatial coverage (approximately 4 Hz off-resonance frequency coverage) because of signal drop-outs related to the SSFP banding artifact. Here we demonstrate that pass-band SSFP fMRI at 7 Tesla using a larger flip angle (20o) with π RF phase cycling can provide high quality images and large spatial coverage with limited signal null (bSSFP banding artifact) areas. The characteristics of the bSSFP functional contrast were also investigated using multi-echo and multi-TR experiments. The results were compared to GRE with matching parameters. METHODS (1) Image quality and spatial coverage: All experiments were performed using a GE 7 T scanner and a NOVA 32 channel head coil. A 3D balanced SSFP sequence with different TRs (5, 7.5, 10 and 12.5 msec) was used to scan entire brain to identify the location of the signal null areas (banding artifacts). To compare image quality bSSFP, GRE EPI and an anatomical reference were acquired. (2) Contrast characteristics: A 3D multi-echo SSFP sequence was scanned at four different TRs (5, 7.5, 10 and 12.5 ms) with 1 to 7 echoes (FOV = 24 x 15.8 cm, resolution = 2 x 2 x 4 mm, α = 20o, number of slices = 6, BW = ±50 kHz). The same parameters were used for a RF spoiled GRE sequence for contrast comparison (n = 4). One each subject, functional data were aligned to the GRE data of TR =12.5 ms. The ROI for the analysis was defined as the commonly activated voxels of the last echo of the TR = 12.5 ms SSFP and GRE data at low threshold (z > 1.57) while excluding the high threshold (z > 3.11) activated voxels of the first echo GRE TR = 12.5ms data to avoid large veins. The ROI was further restricted to visual cortex. RESULTS The signal nulls were observed primarily in limited brain areas including frontal (above the sinus) and temporal (above the ear canal) lobes for the 5 ms TR whole brain scan. The areas spread out to large portions of brain including the occipital lobe for TR=12.5 ms (Fig 1). Compared to the EPI GRE result, SSFP image quality was superior (Fig. 2a and 2b, the red contours were drawn from the anatomical reference). In the fMRI experiment using the bSSFP (TR = 5 and 7.5 ms), the entire visual cortex area was banding free. The activation map shows significant activation in visual cortex area (Fig 3). When the relative signal changes of the multi-echo and multi-TR bSSFP were compared with those of the GRE with the matching parameters, larger percent changes were observed in bSSFP results (Figure 4, TR =5, 7.5, 12.5 ms showed statistically significant results for TE ≈ TR/2 datasets). This result was particularly prominent at the earlier echoes where the GRE results showed close to zero intercepts when extrapolated to TE = 0 whereas bSSFP results suggested significantly large intercept values. This is attributed to the substantial contribution of stimulated echoes (that increase T2 weighting) to the SSFP signal. CONCLUSION AND DISCUSSION Pass-band bSSFP fMRI at 7 Tesla can provide large spatial coverage and high image quality. The results of the multi-echo multi-TR experiments reveal substantial contrast at the early echoes suggesting that the contrast from multiple echo pathways contributes significantly at 7 Tesla for the given parameters.
منابع مشابه
Analysis of the BOLD Signal Characteristics in balanced SSFP fMRI: a Monte-Carlo Simulation
Introduction Recently, balanced SSFP (Steady State Free Precession) has been proposed as an alternative method to measure the BOLD contrast [1-3]. Two different contrast mechanisms have been explored experimentally: (1) transition-band SSFP fMRI (BOSS fMRI) that detects the BOLD induced frequency shift near the transition part of the SSFP profile [1,2], and (2) pass-band SSFP fMRI that is belie...
متن کاملFMRI using balanced steady-state free precession (SSFP)
Steady-state free precession (SSFP) is a highly-efficient MRI pulse sequence that has been a fairly recent arrival in the functional MRI realm. Several methods for using balanced SSFP to detect the BOLD signal have been proposed to date and will be discussed in this review. After a brief introduction to the general properties of SSFP, this review describes the quite different approaches of tran...
متن کاملBOLD fMRI signal characteristics of S1- and S2-SSFP at 7 Tesla
OBJECT To compare the BOLD fMRI signal characteristics at in the cortex and on the pial surface for a non-balanced steady-state free precession sequence (nb-SSFP) at 7 T. MATERIALS AND METHODS A multi-echo nb-SSFP sequence was used for high resolution fMRI at 7 T. Two S1 (S(+)) echoes at different echo times were acquired together with an S2 (S(-)) echo. The primary visual cortex (V1) was exa...
متن کاملReal-time B0 field drift compensation in balanced SSFP: Stabilization of the activation band in transition-band SSFP fMRI
J. Lee, J. M. Santos, J. M. Pauly Electrical Engineering, Stanford University, Stanford, CA, United States Introduction In fMRI experiments, the presence of slow B0 resonance frequency drift is often observed. Several factors, including instrumental instability [1], physiological shifts and subject motion-related-noise are suspected for the causes of this drift. Henry et al. [2] reported that t...
متن کاملImproved 3-Tesla cardiac cine imaging using wideband.
Cine balanced steady-state free precession (SSFP) is the most widely used sequence for assessing cardiac ventricular function at 1.5 T because it provides high signal-to-noise ratio efficiency and strong contrast between myocardium and blood. At 3 T, the use of SSFP is limited by susceptibility-induced off-resonance, resulting in either banding artifacts or the need to use a short-sequence puls...
متن کاملذخیره در منابع من