Temperature-Guided Radiofrequency Catheter Ablation of Accessory Pathway
نویسندگان
چکیده
OBJECTIVES This study was performed to evaluate the usefulness of temperature-guided radiofrequency catheter ablation for the elimination of accessory pathway conduction in patients with Wolff-Parkinson-White syndrome. METHODS Temperature-guided radiofrequency catheter ablation was attempted in 138 patients with 144 accessory pathways (88 pathways along the left free wall, 5 in the anteroseptal region, 2 in the midseptal region, 19 in the posteroseptal region and 30 along the right free wall). The energy source was a HAT 200S which regulated the power automatically to the set temperature of 70 degrees C. Radiofrequency current was delivered through a thermocatheter to the atrial or ventricular side of mitral or tricuspid annulus. RESULTS Accessory pathway conduction was eliminated in 130 of 144 pathways (90.3%). The mean power outputs of the successful ablations at the atrial side of the annulus were higher than those at the ventricular side (34.0 +/- 8.9W versus 20.0 +/- 7.6W, p < 0.01), but the maximum temperatures were lower at the atrial side of the annulus than those at the ventricular side (66.4 +/- 14.0 degrees C versus 77.2 +/- 6.4 degrees C, p < 0.01). There were 3 non-fatal complications (2.1%), 2 patients with hemopericardium and 1 with femoral artery thrombus, during or after ablation procedures. Recurrences of AV re-entrant tachycardia or delta wave on the electrocardiogram occurred in 4 patients (2.8%) who had successful second procedures. There were no late complications during a mean follow-up period of 41 +/- 25 months (range, 3 to 55). CONCLUSION We conclude that 1) temperature-guided radiofrequency catheter ablation can be performed reliably and safely in eliminating accessory pathway conduction in patients with WPW syndrome, and 2) temperature monitoring and adjustment of the power to the set temperature during ablation would be useful for the avoidance of impedance rises and coagulum formation.
منابع مشابه
Radiofrequency catheter ablation in the treatment of Wolff-Parkinson-White syndrome
Introduction: Tachyarrhythmias in Wolf Parkinson White (WPW) syndrome, can be a life threatening factor. Antiarrhythmic drug therapy in this syndrome, has not been completely acceptable. Efficacy, safety and economy of Radio Frequency Catheter Ablation (RFCA) in western studies, has made it as the treatment of choice. In the present study, efficacy of RFCA in the ablation of accessory pathway...
متن کاملTemperature-controlled radiofrequency catheter ablation of manifest accessory pathways.
OBJECTIVES The primary objectives of this study were to assess the feasibility of temperature-controlled radiofrequency catheter ablation of left and right sided manifest accessory pathways in patients with Wolff-Parkinson-White syndrome and to gain more insights into biophysical aspects of temperature-controlled catheter ablation in humans. BACKGROUND The electrode-tissue interface temperatu...
متن کاملConduction During Radiofrequency Current Catheter Ablation of Midseptal Accessory Pathways
Background. Septal accessory atrioventricular (AV) pathways may be located in close vicinity of the His bundle-AV nodal conduction system. Attempts at surgical or electrical interruption of these pathways may therefore result in impairment of normal AV conduction. This study focuses on a subset of septal pathways with an atrial insertion located inside the triangle of Koch. In this study, they ...
متن کاملPreservation of atrioventricular nodal conduction during radiofrequency current catheter ablation of midseptal accessory pathways.
BACKGROUND Septal accessory atrioventricular (AV) pathways may be located in close vicinity of the His bundle-AV nodal conduction system. Attempts at surgical or electrical interruption of these pathways may therefore result in impairment of normal AV conduction. This study focuses on a subset of septal pathways with an atrial insertion located inside the triangle of Koch. In this study, they w...
متن کاملSite of accessory pathway block after radiofrequency catheter ablation in patients with the Wolff-Parkinson-White syndrome.
INTRODUCTION Recent studies have demonstrated that the most common site of accessory pathway conduction block following the introduction of a premature atrial stimulus during atrial pacing is between the accessory pathway potential and the ventricular electrogram, consistent with block at the ventricular insertion of the accessory pathway. However, no prior study has evaluated the site of condu...
متن کامل