Comparing hepatic 2D and 3D magnetic resonance elastography methods in a clinical setting - Initial experiences.
نویسندگان
چکیده
PURPOSE Continuous monitoring of liver fibrosis progression in patients is not feasible with the current diagnostic golden standard (needle biopsy). Recently, magnetic resonance elastography (MRE) has emerged as a promising method for such continuous monitoring. Since there are different MRE methods that could be used in a clinical setting there is a need to investigate whether measurements produced by these MRE methods are comparable. Hence, the purpose of this pilot study was to evaluate whether the measurements of the viscoelastic properties produced by 2D (stiffness) and 3D (elasticity and 'G abs,Elastic') MRE are comparable. MATERIALS AND METHODS Seven patients with diffuse or suspect diffuse liver disease were examined in the same day with the two MRE methods. 2D MRE was performed using an acoustic passive transducer, with a 1.5 T GE 450 W MR system. 3D MRE was performed using an electromagnetic active transducer, with a 1.5 T Philips Achieva MR system. Finally, mean viscoelastic values were extracted from the same anatomical region for both methods by an experienced radiologist. RESULTS Stiffness correlated well with the elasticity, R (2) = 0.96 (P < 0.001; slope = 1.08, intercept = 0.61 kPa), as well as with 'G abs,Elastic' R (2) = 0.96 (P < 0.001; slope = 0.95, intercept = 0.28 kPa). CONCLUSION This pilot study shows that different MRE methods can produce comparable measurements of the viscoelastic properties of the liver. The existence of such comparable measurements is important, both from a clinical as well as a research perspective, since it allows for equipment-independent monitoring of disease progression.
منابع مشابه
‘Image-navigated 3-dimensional late gadolinium enhancement cardiovascular magnetic resonance imaging: feasibility and initial clinical results’
BACKGROUND Image-navigated 3-dimensional late gadolinium enhancement (iNAV-3D LGE) is an advanced imaging technique that allows for direct respiratory motion correction of the heart. Its feasibility in a routine clinical setting has not been validated. METHODS Twenty-three consecutive patients referred for cardiovascular magnetic resonance (CMR) examination including late gadolinium enhanceme...
متن کاملAblation Monitoring with Elastography: 2D In-vivoand 3D Ex-vivoStudies
The clinical feasibility of 2D elastography methods is hindered by the requirement that the operator avoid out-of-plane motion of the ultrasound image during palpation, and also by the lack of volumetric elastography measurements. In this paper, we develop and evaluate a 3D elastography method operating on volumetric data acquired from a 3D probe. Our method is based on minimizing a cost functi...
متن کاملTowards compression-sensitive magnetic resonance elastography of the liver: sensitivity of harmonic volumetric strain to portal hypertension.
PURPOSE To assess induced oscillating volumetric strain as a biomarker for intrahepatic blood pressure abnormalities. MATERIALS AND METHODS Harmonic vibrations of 25 and 50 Hz frequency were induced in the liver and measured by fast 3D vector field magnetic resonance elastography (MRE), followed by processing of the decomposed curl (shear) and divergence (compression) fields. After an initial...
متن کاملبررسی خواص مغناطیسی تک اتمهای فلزات واسط 3d افزوده شده بر روی بورن نیتراید شش گوشی دوبعدی
In the frame work of relativistic density functional theory, using full potential local orbital band structure scheme (FPLO), the magnetic properties of single 3d transition metals (3d-TM) adsorbed on 2D hexagonal boron nitride (2D h-BN) are investigated. Binding energies between 3d-TM adatoms and 2D h-BN in three different compositions, local spin magnetic moments of 3d-TM and total spin magne...
متن کاملApplications of magnetic resonance elastography to healthy and pathologic skeletal muscle.
Magnetic resonance elastography (MRE) is capable of noninvasively quantifying the mechanical properties of skeletal muscles in vivo. This information can be clinically useful to understand the effects of pathologies on the mechanical properties of muscle and to quantify the effects of treatment. Advances in inversion algorithms quantify muscle anisotropy in two-dimensional (2D) and three-dimens...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of radiology open
دوره 2 شماره
صفحات -
تاریخ انتشار 2015