The elastic modulus of canine aortic valve leaflets in vivo and in vitro.

نویسندگان

  • M Thubrikar
  • W C Piepgrass
  • L P Bosher
  • S P Nolan
چکیده

Aortic valve leaflets undergo extraordinary flexion due to the complete reversal of their curvature during billions of cardiac cycles. The flexion stresses in the leaflet depend on its elastic modulus which we investigated in vivo and in vitro. In six dogs, we placed radiopaque markers on an aortic leaflet. Leaflet length was calculated from the marker positions recorded fluoroscopically. Aortic and ventricular pressures were recorded. Dogs were killed and leaflet stress-strain curves determined in vitro. Leaflet length in vivo decreased 10.4 +/- 4.7% from diastole to systole in each cardiac cycle. Using the law of LaPlace, pressure gradients across the leaflets were converted into the stresses in the leaflets. The leaflets had an initial "elastic phase" of low modulus in systole followed by an "inelastic phase" of high modulus in diastole. The elastic modulus was 2.4 +/- 0.7 x 10(6) dynes/cm2 in systole and 5.2 +/- 1.7 x 10(7) dynes/cm2 in diastole. These results were similar to those obtained in vitro. Since flexion rigidity is proportional to (elastic modulus) x (thickness)3, the lower modulus in systole greatly reduces flexion stresses in the leaflet and increases leaflet longevity. The higher elastic modulus in diastole prevents excessive bulging or prolapse of the leaflet while it is subjected to the diastolic pressure gradient. We conclude that a natural or prosthetic leaflet which is thickened or has a high elastic modulus throughout the cardiac cycle will have a greater flexion stress that could cause early failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

گزارش 3 بیمار مبتلا به تونل آئورت به بطن چپ

Aorto-left ventricular tunnel (ALVT) is a rare congenital anomaly in which an abnormal communication connects the ascending aorta with the left ventricle, that results volume overload on left ventricle. It is clinically undistinguishable from aortic insufficiency. Its prompt and precise diagnosis is crucial since early surgical treatment is definitely indicated. In this report clinical,...

متن کامل

Opening and closing characteristics of the aortic valve after valve-sparing procedures using a new aortic root conduit.

BACKGROUND The durability of aortic valve-sparing procedures is negatively affected by increased leaflet stress in the absence of normally shaped sinuses of Valsalva. We compared valve motion after remodeling procedures using a standard conduit and a specifically designed aortic root conduit. METHODS Echocardiographic studies of the aortic valve dynamics were performed in 14 patients after re...

متن کامل

Planar biaxial behavior of fibrin-based tissue-engineered heart valve leaflets.

To design more effective tissue-engineered heart valve replacements, the replacement tissue may need to mimic the biaxial stress-strain behavior of native heart valve tissue. This study characterized the planar biaxial properties of tissue-engineered valve leaflets and native aortic valve leaflets. Fibrin-based valve equivalent (VE) and porcine aortic valve (PAV) leaflets were subjected to incr...

متن کامل

تخمین غیرتهاجمی مدول الاستیک چشم کاتاراکته شده خرگوش

    Although cataract is very common and its detection seems apparently easy especially in the mature cataract, its quantitative description to determine the critical value of diagnosis is too difficult. Non-invasive evaluation of the mechanical properties of eye is hampered by the absence of in-vivo methods for direct assessment of the axial length of eye, lens and cornea. In the present study...

متن کامل

Measurements of Young's modulus of elasticity of the canine aorta with ultrasound.

We have developed an ultrasonic technique for determining the dynamic Young's modulus of elasticity (E) of the canine aorta in vivo. Young's modulus was measured in the descending thoracic aorta (DTA) and the abdominal aorta (AA) of 12 dogs over a range of mean blood pressures from 40-200 mmHg. The vessels were excised and dynamic moduli were determined in vitro postmortem from pressure-volume ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 47 5  شماره 

صفحات  -

تاریخ انتشار 1980