Influence of the dynamometer and knee joint axis of rotation alignment on the isokinetic measurements

نویسندگان

  • J. L. Croisier
  • P. Ciavatta
  • B. Forthomme
چکیده

Influence of the dynamometer and knee joint axis of rotation alignment on the isokinetic measurements J.L. Croisier, P. Ciavatta and B. Forthomme Department of Physical Medicine and Rehabilitation, University of Liege, Belgium E-mail: [email protected] Objectives: Factors that could influence accuracy of isokinetic assessment deserve careful attention [1,2]. In order to develop accurate and standardized test protocols, many investigations have focused for instance on gravity correction, visual feedback, range of motion, resistance pad position. The aim of our study was to determine the consequences of an inappropriate alignment between the dynamometer and knee joint axis of rotation on isokinetic measurements. Methods: Twelve healthy male subjects (24 ± 2 years old) participated in one session of testing (Cybex Norm dynamometer) on their dominant leg. Four conditions of proper or intentionally altered (in the horizontal plane) alignment were randomly proposed. Based on proper alignment with the knee flexed at 90◦, the altered alignments were designed as follows: joint axis of rotation placed 6 cm (−6) and 12 cm (−12) behind or 6 cm (+ 6) in front of the dynamometer axis of rotation in the horizontal plane (Fig. 1). Knee flexors and extensors performed 3 maximal repetitions for testing at 60◦/s in the concentric mode throughout a constant 100◦ range of motion. Subjects benefited from 3 preliminary submaximal trials for familiarization before the successive testing positions. Descriptive statistics and ANOVA tests were used to analyze the data. Results: For both knee flexors (Fl) and quadriceps (Q), measurements in the properly aligned and + 6 positions showed no significant difference in peak torque (PT) (Fig. 2). By contrast, the PT corresponding to the joint 12 6 Aligned + 6 Fig. 1. Representation of proper and altered alignments between the knee joint and dynamometer axis of rotation. axis of rotation placed behind the device axis of rotation (−6 and −12) were significantly (p < 0.05) decreased for both muscle groups, most notably on the quadriceps in the −12 position (−14% for that position compared to the properly aligned). The same observations characterized the work parameter, even though the Fl/Q ratio calculated from PT was not significantly influenced by the alignment ISSN 0959-3020/05/$17.00  2005 – IOS Press and the authors. All rights reserved 4 J.L. Croisier et al. / Influence of the dynamometer and knee joint axis of rotation alignment on the isokinetic measurements 0 50 100 150 200 250 300 Aligned -6 -12 +6 Aligned -6 -12 +6 P T ( N .m ) a b b a a a b b Extensors Flexors Fig. 2. Concentric peak torques (PT in N.m) developed by knee extensors and flexors at 60◦/s: comparative study between proper or altered alignments. Different letters represent statistically significant differences (p < 0.05). modalities. Conclusion: We highlighted the influence of an improper alignment between the knee joint and dynamometer axis of rotation, particularly when the joint is positioned behind the dynamometer motor in the horizontal plane. A lack of precision on that point would introduce a factor confounding accurate isokinetic assessment. References [1] Z. Dvir, Isokinetics. Muscle testing, interpretation and clinical applications, (second edition), Churchill Livingston, 2004. [2] D.H. Perrin, Isokinetic exercise and assessment, Human Kinetics Publisher, 1993. Isokinetics and Exercise Science 13 (2005) 5–11 5 IOS Press Activation EMG pattern during isokinetic knee flexion-extension assessment: Comparison between healthy subjects and chronic pain patients D. Maquet, C. Demoulin, B. Forthomme, J.M. Crielaard and J.L. Croisier Department of Physical Medicine and Rehabilitation, University of Li ège, Belgium ISEPK, B21, Allée des Sports 4, 4000 Liege, Belgium

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)

    Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...

متن کامل

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

The Comparison of Isokinetic Parameters of Hip and Knee Joint Muscles in Professional Soccer Players with Athletic Groin Pain and Healthy One: Implications for Sports Injuries Prevention

Aims and background: This study aimed to investigate the comparison of isokinetic parameters of hip and knee joint muscles in professional soccer players with athletic groin pain (AGP) and healthy ones. Material and Methods: 32 soccer players (control group (n=16) and AGP group (n=16)) who take part in the first and second division league participated in this study. The isokinetic dynamometer ...

متن کامل

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

  Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...