Screening Characteristics of Bedside Ultrasonography in Confirming Endotracheal Tube Placement; a Diagnostic Accuracy Study

نویسندگان

  • Hamid Zamani Moghadam
  • Mohamad Davood Sharifi
  • Hasan Rajabi
  • Mojtaba Mousavi Bazaz
  • Ali Alamdaran
  • Niazmohammad Jafari
  • Seyed Amir Masoud Hashemian
  • Morteza Talebi Deloei
چکیده

INTRODUCTION Confirmation of proper endotracheal tube placement is one of the most important and lifesaving issues of tracheal intubation. The present study was aimed to evaluate the accuracy of tracheal ultrasonography by emergency residents in this regard. METHOD This was a prospective, cross sectional study for evaluating the diagnostic accuracy of ultrasonography in endotracheal tube placement confirmation compared to a combination of 4 clinical confirmation methods of chest and epigastric auscultation, direct laryngoscopy, aspiration of the tube, and pulse oximetry (as reference test). RESULTS 150 patients with the mean age of 58.52 ± 1.73 years were included (56.6% male). Sensitivity, specificity, positive predictive value, negative predictive value, and positive and negative likelihood ratio of tracheal ultrasonography in endotracheal tube confirmation were 96 (95% CI: 92-99), 88 (95% CI: 62-97), 98 (95% CI: 94-99), 78 (95% CI: 53-93), 64 (95% CI: 16-255), and 0.2 (95% CI: 0.1-0.6), respectively. CONCLUSION The present study showed that tracheal ultrasonography by trained emergency medicine residents had excellent sensitivity (>90%) and good specificity (80-90) for confirming endotracheal tube placement. Therefore, it seems that ultrasonography is a proper screening tool in determining endotracheal tube placement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A feasibility study on bedside upper airway ultrasonography compared to waveform capnography for verifying endotracheal tube location after intubation

BACKGROUND In emergency settings, verification of endotracheal tube (ETT) location is important for critically ill patients. Ignorance of oesophageal intubation can be disastrous. Many methods are used for verification of the endotracheal tube location; none are ideal. Quantitative waveform capnography is considered the standard of care for this purpose but is not always available and is expens...

متن کامل

Confirming nasogastric tube position: methods & restrictions: A narrative review

Background and Purpose: Inserting a nasogastric tube, though a common clinical procedure with widespread use for critically ill patients, can produce unexpected complications so that tube misplacement into the lungs is a potential complication with serious consequences. The reliability of common bedside methods to differentiate between pulmonary and gastric placement has not been acceptable. Th...

متن کامل

بررسی دقت سونوگرافی بر بالین بیمار برای تشخیص پنوموتوراکس در بخش اورژانس بیمارستان حضرت رسول اکرم (ص) در سال 1387

Background: Pneumothorax may be associated with penetrating or blunt chest traumas' that need early diagnosis and treatment. Today the diagnosis modalities are CXR and CT-Scan that are not suitable for unstable patients. Chest sonography can be a fast diagnostic method at patient bedside. The purpose of this study was to evaluate the accuracy of bedside ultrasonography in diagnosis of pneumotho...

متن کامل

End-tidal capnography and upper airway ultrasonography in the rapid confirmation of endotracheal tube placement in patients requiring intubation for general anaesthesia

BACKGROUND AND AIMS Confirmation of correct endotracheal tube placement is essential immediately after intubation for general anaesthesia. In this study, we have compared upper airway ultrasonography (USG) with reference to capnography for rapid confirmation of endotracheal tube placement after general anaesthesia. METHODS A prospective, single centre, observational study was conducted on 100...

متن کامل

Inflating the endotracheal tube cuff with saline to confirm correct depth using bedside ultrasonography.

Although bedside ultrasonography can accurately distinguish esophageal from tracheal intubation, it is not used to establish the correct depth of endotracheal tube insertion. As indirect sonographic markers of endotracheal tube insertion depth have proven unreliable, a method for visual verification of correct tube depth would be ideal. We describe the use of saline to inflate the endotracheal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017