The compact electron cyclotron resonance ion source KeiGM for the carbon ion therapy facility at Gunma University.

نویسندگان

  • M Muramatsu
  • A Kitagawa
  • A G Drentje
  • S Hojo
  • T Ueda
  • H Miyazaki
  • K Yusa
  • M Tashiro
  • K Torikai
  • M Sakama
  • T Kanai
  • S Yamada
چکیده

A high-energy carbon-ion radiotherapy facility is under construction at Gunma University Heavy Ion Medical Centre (GHMC). Its design was based on a study of the heavy ion radiotherapy at the National Institute of Radiological Sciences (NIRS) in order to reduce the size and construction cost of the facility. A compact electron cyclotron resonance ion source (ECRIS) for Gunma University, called KeiGM, was installed in 2008. It is almost a copy of the prototype ECRIS Kei2 which was developed by NIRS; meanwhile this prototype produced over 1 e mA of C(4+) using C(2)H(2) gas (660 W and 40 kV). The beam intensity of C(4+) was 600 e microA with CH(4) gas (250 W and 30 kV). The beam intensity satisfies the required value of 300 e microA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Operation of Keigm for the Carbon Ion Therapy Facility at Gunma University

Carbon-ion radiotherapy is being carried out at Gunma University Heavy Ion Medical Centre (GHMC) since March 2010. A compact electron cyclotron resonance ion source (ECRIS) for GHMC, so-called KeiGM, supplies carbon 4+ ions for treatment. The general structure of KeiGM was copied from a prototype compact source, socalled Kei2. Based on experimental studies for production of carbon 4+ ions with ...

متن کامل

The Preparation, Characterization and Tribological Properties of TA-C:H Deposited Using an Electron Cyclotron Wave Resonance Plasma Beam Source

A compact electron cyclotron wave resonance (ECWR) source has been developed for the high rate deposition of hydrogenated tetrahedral amorphous carbon (ta-C : H). The ECWR provides growth rates of up to 900 AÊ /min over a 400 diameter and an independent control of the deposition rate and ion energy. The ta-C : H was deposited using acetylene as the source gas and was characterized in terms of i...

متن کامل

Design of a Compact All-permanent Magnet Ecr Ion Source Injector for Rea at the Msu Nscl

The design of a compact all-permanent magnet electron cyclotron resonance (ECR) ion source injector for the ReAccelerator Facility (ReA) at the Michigan State University (MSU) National Superconducting Cyclotron Laboratory (NSCL) is currently being carried out. The ECR ion source injector will augment the electron beam ion trap (EBIT) charge breeder as an off-line stable ion beam injector for th...

متن کامل

Carbon Ion Radiotherapy at the Gunma University Heavy Ion Medical Center: New Facility Set-up

Carbon ion radiotherapy (C-ion RT) offers superior dose conformity in the treatment of deep-seated tumors compared with conventional X-ray therapy. In addition, carbon ion beams have a higher relative biological effectiveness compared with protons or X-ray beams. C-ion RT for the first patient at Gunma University Heavy Ion Medical Center (GHMC) was initiated in March of 2010. The major specific...

متن کامل

Recent Progress of Heavy-ion Cancer Radiotherapy with Nirs-himac

The carbon-ion radiotherapy (RT) with HIMAC has been conducted since 1994, and the accumulated number of patients treated exceeded 7,500 in July 2013. On the basis of the HIMAC experience, NIRS developed a compact carbon-ion RT facility in order to boost the carbon-ion RT in Japan, and a pilot facility of this work was constructed and conducted at the Gunma University. Toward the further develo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 81 2  شماره 

صفحات  -

تاریخ انتشار 2010