Determination of linear x-ray attenuation coefficients of pathological brain tissues and use of filters in tissue contrast enhancement in computed tomography.

نویسندگان

  • M Erdem Sagsoz
  • Fazlı Erdogan
  • Salih Z Erzeneoglu
  • İhsan Yuce
چکیده

OBJECTIVE X-ray attenuation coefficients are used in common radiological, pathological and spectroscopic examinations and in the determination of the radiation dose distribution in biological tissues. In radiology, these coefficients enable diagnosis by differentiating the abnormal tissues from the normal ones using their morphological structure and contrast differences. In this study, our aim is to precisely determine the linear x-ray attenuation coefficients of pathological brain tissues and to use x-ray beam filters to enhance the tissue contrast in computed tomography. MATERIALS AND METHODS To directly measure the relative linear attenuation coefficients, an energy dispersive x-ray spectroscopy system (EDXRS-Canberra, Si(Li) with DSA-1000 spectrum analyzer 1998; CT, USA) was used with collimators and a medical-purpose x-ray tube (Siemens, Siremobil, 1985; Erlangen, Germany) in a linear geometry. RESULTS Using a Mo filter with Computed Tomography CT and photon energies from 15 to 25 keV, EDXRS acquisitions were found to significantly distinguish grades of brain tumors (p<0.05). For the data acquired from CT systems with the decreasing filtered photon mean energy, the x-ray attenuation coefficients (i.e., the Hounsfield units) show that the ratio of EDXRS to CT for water's attenuation coefficient are increased. With our suggested x-ray filters, the tissue contrast has been found to be increased in ex vivo brain tumor slices compared with slices scanned in conventional CT scanners. CONCLUSION X-ray attenuations measured with the EDXRS are found to be statistically more reliable because of the length of acquisition times in this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An iterative method to estimate x-ray attenuation coefficients in computed tomography

Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (D...

متن کامل

Histogram analysis- a useful tool for tissue characterization in brain CT

Introduction: Pixel value in computed tomography (CT) gives the average linear attenuation coefficient of the scanned material in the path of the x-ray beam, being normalized to that of water. It is known that attenuation coefficient or HU value is a function of the chemical characteristic of the material and of the x-ray energy. The CT image shows the HU value by a shade of gr...

متن کامل

Evaluation of effect of gold nanorods and spherical gold nanoparticles of different sizes on X-ray attenuation in computed tomography

Introduction: To date, gold nanoparticles (GNPs) have been demonstrated to have great potential as contrast agent for CT imaging and therapeutics. This study was designed to evaluate any effect on X-ray attenuation that might result from using GNPs with a variety of size, surface chemistries and shapes.   Materials and Methods: Spherical GNPs and gold nanorod...

متن کامل

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

Evaluation of multifunctional targeted gold nanoparticles on X-ray attenuation in nasopharyngeal cancer cells by X- ray imaging

Introduction: Head-and-neck cancer is the sixth most common cancer worldwide with the number of cases consistently increasing in developing countries. Successful development of effective, safe and cost effective nanoprobes for head-and-neck cancer targeting imaging is a big challenge. This study is aimed to develop cysteamine-folate conjugated gold nanoparticles (F-Cys-AuNPs) a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Eurasian journal of medicine

دوره 42 2  شماره 

صفحات  -

تاریخ انتشار 2010