Phonoangiography by autocorrelation.
نویسندگان
چکیده
Phonoangiography, as a noninvasive quantitative analysis of arterial bruits, was conducted just prior to standard invasive radiographic angiography in 135 patients. Sound records from 162 carotid arteries were analyzed with a new processing technique employing a high speed analog acoustic analyzer, the autocorrelator. In 18 arteries with carotid stenosis, a correlation coefficient of 0.87 resulted between phonoangiographic diameter predictions and radiographic diameter estimates. Bruit analysis identified two patients with patent lumen diameters, but tortuous carotid vessels. One hundred thirty-three carotid arteries had no bruits that could be analyzed, but angiograms showed no extracranial stenosis. Four arteries from which bruits could not be analyzed were found to be totally occluded. Carotid phonoangiography appears applicable in approximately one of seven patients now requiring angiography of head and neck vessels. When applicable, phonoangiography is significantly correlated with angiographic findings.
منابع مشابه
The bruit of carotid stenosis versus radiated basal heart murmurs. Differentiation by phonoangiography.
Phonoangiography, quantitative analysis of arterial bruits, has been shown to provide accurate noninvasive diagnosis of uncomplicated carotid arterial stenosis, but had not been tested where cervical bruits from other sources were present. In this study, 27 carotid bruits in 15 consecutive patients with carotid bruits and basal heart murmurs were analyzed by phonoangiography. Tape recordings we...
متن کاملNoninvasive testing for carotid artery stenosis: I. Prospective analysis of three methods.
Oculoplethysmography-carotid phonoangiography and periorbital directional Doppler sonography are two techniques widely used in the noninvasive evaluation of possible carotid artery disease. Recent advances with sonographic Doppler devices now permit measurement of blood velocities in the extracranial carotid arteries by direct scanning with a color coded Doppler imaging system. A prospective st...
متن کاملQuantitative carotid phonoangiography.
One hundred and sixteen carotid artery bruits were assessed using quantitative phonoangiography (spectral bruit analysis - SBA). This technique uses the averaged break frequency of the bruit to calculate the diameter of he residual lumen at the site of stenosis. Biplanar contrast arteriography was performed on 43 (37%) of the sides. All 116 sides were also evaluated with an ultrasonic Duplex sc...
متن کاملUse of combined oculoplethysmography, carotid phonoangiography and Doppler in the non-invasive diagnosis of extracranial carotid occlusive disease.
One hundred and eight patients were studied with fluid-filled oculoplethysmography and carotid phonoangiography (OPG-CPA) and by arteriography. Thirty-two patients also had "Doppler evaluation" of supraorbital arterial flow. The OPG-CPA correctly predicted the degree of occlusion in 76% of the involved vessels, including the degree of occlusion of each carotid for each patient (63%). The OPG-CP...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 55 4 شماره
صفحات -
تاریخ انتشار 1977