Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults

نویسندگان

  • Han Chen
  • Gui-Sheng Ding
  • Yan-Chun Zhao
  • Rong-Guo Yu
  • Jian-Xin Zhou
چکیده

BACKGROUND Measurement of optic nerve sheath diameter (ONSD) is a fast and non-invasive method in detecting elevated intracranial pressure. However, the reported normal range of ONSD was inconsistent. The objective of the study was to determine the normal range of ONSD in healthy Chinese adults. METHODS Eyeball transverse diameter (ETD), optic nerve diameter (OND), and ONSD were measured by ultrasound examination in healthy adult volunteers. The OND and ONSD were assessed 3 mm behind the globe. The section showing maximal transverse diameter of the eyeball was frozen and the diameter was measured. Each ETD, OND and ONSD was examined twice and the mean value was calculated. RESULTS A total of 519 healthy volunteers were included in the study. The median (interquartile range) of ETD, OND and ONSD were 22.3 (21.6 to 23.1) mm, 3.2 (2.9 to 3.4) mm, and 5.1 (4.7 to 5.4) mm, respectively. The 95% percentile of ONSD was 5.9 mm. There was no significant difference in ETD, OND or ONSD between male and female, or between left and right eye. ONSD was significantly correlated with OND (r = 0.62, P < 0.001), and the median OND/ONSD ratio (interquartile range) was 0.63 (0.59 to 0.67). CONCLUSIONS The median and the 95% percentile of sonographic measurement of ONSD are 5.1 mm and 5.9 mm in healthy Chinese adults. The ONSD is correlated with OND, while independent of gender, age, height, weight and ETD. The median OND/ONSD ratio is 0.63 and this parameter warrants further investigation in patients with brain injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of scuba-diving on optic nerve and sheath diameters

  Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated.   Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...

متن کامل

Comparative study measuring optic nerve sheath diameter by transorbital ultrasound in healthy women, pregnant women and pregnant with preeclampsia / eclampsia

Introduction Preeclampsia / eclampsia is a potentially serious disease associated with maternal complications, including neurological. In patients with increased intracranial pressure, the diameter of the optic nerve sheath increases because of its close association with the flow of cerebrospinal fluid. Her measurements using ultrasound transorbital have shown correlation with increased intracr...

متن کامل

Coronal Axis Measurement of the Optic Nerve Sheath Diameter.

OBJECTIVES The true optic nerve sheath diameter cutoff value for detecting elevated intracranial pressure is variable. The variability may stem from the technique used to acquire sonographic measurements of the optic nerve sheath diameter as well as sonographic artifacts inherent to the technique. The purpose of this study was to compare the traditional visual axis technique to an infraorbital ...

متن کامل

Correlation of visual axis and coronal axis measurements of the optic nerve sheath diameter.

OBJECTIVE There are several approaches to sonographic imaging and measurement of the optic nerve sheath diameter (ONSD). In this study, we sought to compare visual axis measurements of the optic nerve sheath (ONS) with traditional coronal axis measurements to assess for correlation. METHODS The ONS was visualized in 2 views on both eyes of healthy volunteers using an 8.5-MHz probe. Coronal ax...

متن کامل

SCIENTIFIC CORRESPONDENCE Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus

Aim: To evaluate the utility of measuring the optic nerve sheath diameter in children with shunted hydrocephalus, suspected of having raised intracranial pressure. Methods: 23 children with shunted hydrocephalus were examined, six had well controlled ICP, 17 however manifested symptoms suggestive of intracranial hypertension. A clinical history was taken from all patients and their parents or c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015